PubMed Health⌕ Search

PubMed · 16808605

External dose estimation for nuclear worker studies.

Abstract

Epidemiological studies of nuclear workers are an important source of direct information on the health effects of exposure to radiation at low doses and low dose rates. These studies have the important advantage of doses that have been measured objectively through the use of personal dosimeters. However, to make valid comparisons of worker-based estimates with those obtained from data on A-bomb survivors or persons exposed for medical reasons, attention must be given to potential biases and uncertainties in dose estimates. This paper discusses sources of error in worker dose estimates and describes efforts that have been made to quantify these errors. Of particular importance is the extensive study of errors in dosimetry that was conducted as part of a large collaborative study of nuclear workers in 15 countries being coordinated by the International Agency for Research on Cancer. The study, which focused on workers whose dose was primarily from penetrating gamma radiation in the range 100 keV to 3 MeV, included (1) obtaining information on dosimetry practices and radiation characteristics through the use of questionnaires; (2) two detailed studies of exposure conditions, one of nuclear power plants and the other of mixed activity facilities; and (3) a study of dosimeter response characteristics that included laboratory testing of 10 dosimeter designs commonly used historically. Based on these efforts, facility- and calendar year-specific adjustment factors have been developed, which will allow risks to be expressed as functions of organ doses with reasonable confidence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E S Gilbert, I Thierry-Chef, E Cardis, J J Fix, M Marshall. 2006. External dose estimation for nuclear worker studies.. https://doi.org/10.1667/rr3126.1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗