Quality and performance measures in bone densitometry: part 1: errors and diagnosis.

Abstract

INTRODUCTION: Bone densitometry is one of the main pillars in the assessment of osteoporosis. The most important modalities are dual x-ray absorptiometry (DXA), quantitative computed tomography (QCT), and quantitative ultrasound (QUS). MATERIALS AND METHODS: For each modality a variety of technical solutions and numerous commercial devices are available and widely used for patient measurements. While the field of bone densitometry may be considered mature, new modalities and devices are being introduced. Consequently, there is a constant need to assess and compare the quality of bone densitometry approaches and devices in a rigorous way. RESULTS: The International Commission on Radiation Units has commissioned a report on bone densitometry to address some of these issues, in particular to provide clear definitions of quantities and units used and to describe parameters and methods that can be used to compare and standardize densitometric equipment and measurements. One of the core chapters of the report summarizes quality and performance measures in bone densitometry. It is divided into four sections: physical performance measures, diagnosis, fracture risk, and monitoring. Here we publish part 1 of this chapter containing the first two sections: physical performance measures and issues in diagnosing osteoporosis. CONCLUSION: Following the international standard (ISO 5725-1), trueness, bias, repeatability, and reproducibility are defined along with terms common to osteoporosis research, such as accuracy and precision. Building on the conceptual definition of osteoporosis, diagnostic criteria are defined and discussed including criteria for reference data. Based on this, clinical performance measures commonly used for the diagnosis of osteoporosis are reviewed and discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Engelke, C-C Glüer. 2006-07-04. Quality and performance measures in bone densitometry: part 1: errors and diagnosis.. https://doi.org/10.1007/s00198-005-0039-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗