PubMed Health⌕ Search

PubMed · 16845271

Predictive testing for complex diseases using multiple genes: fact or fiction?

Abstract

PURPOSE: There is ongoing debate about whether testing low-risk genes at multiple loci will be useful in clinical care and public health. We investigated the usefulness of multiple genetic testing using simulated data. METHODS: Usefulness was evaluated by the area under the receiver-operating characteristic curve (AUC), which indicates the accuracy of genetic profiling in discriminating between future patients and nonpatients. The AUC was investigated in relation to the number of genes assumed to be involved, the risk allele frequency, the odds ratio of the risk genotypes, and to the proportion of variance explained by genetic factors as an approximation of the heritability of the disease. RESULTS: We demonstrated that a high (AUC > 0.80) to excellent discriminative accuracy (AUC > 0.95) can be obtained by simultaneously testing multiple susceptibility genes. A higher discriminative accuracy is obtained when genetic factors play a larger role in the disease, as indicated by the proportion of explained variance. The maximum discriminative accuracy of future genetic profiling can be estimated at present from the heritability and prevalence of disease. CONCLUSIONS: Genetic profiling may have the potential to identify individuals at higher risk of disease depending on the prevalence and heritability of the disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Cecile J W Janssens, Yurii S Aulchenko, Stefano Elefante, Gerard J J M Borsboom, Ewout W Steyerberg, Cornelia M van Duijn. 2006. Predictive testing for complex diseases using multiple genes: fact or fiction?. https://doi.org/10.1097/01.gim.0000229689.18263.f4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Smooth semiparametric receiver operating characteristic curves for continuous diagnostic tests.

We propose a semiparametric kernel distribution function estimator, based on which a new smooth semiparametric estimator of the receiver operating characteristic (ROC) curve is constructed. We derive the asymptotic bias and variance of the newly proposed distribution function estimator and show that it is more efficient than the traditional non-parametric kernel distribution estimator. We also derive the asymptotic bias and variance of our new ROC curve estimator and show that it is more efficient than the smooth non-parametric ROC curve estimator proposed by Zou et al. (Stat. Med. 1997; 16:2143-2156) and Lloyd (J. Am. Stat. Assoc. 1998; 93:1356-1364). For our proposed estimators, we derive data-based methods for bandwidth selection. In addition, we present some results on the analysis of two real data sets. Finally, a simulation study is presented to show that our estimators are better than the non-parametric counterparts in terms of bias, standard error, and mean-square error.

Area Under Curve↗

Redox potential measurement as a rapid method for microbiological testing and its validation for coliform determination.

The redox potential is one of the most complex indicators of the physiological state of microbial cultures and its measurement could be a useful tool for the qualitative and quantitative determination of the microbial contamination. During the bacterial growth, the redox potential of the medium decreases. The shape of the redox potential curve is characteristic on the type of microorganism, and the rate of the change (dE/dt) is proportional to the living cell concentration. Defining the time required to reach a significant change in redox potential as Time to Detection (TTD), similarly to the impedimetric measurements, a strict linear correlation could be established between the TTD and the logarithm of the initial concentration of microorganisms. On the base of this calibration curve, the determination of living cell concentration could be simplified. For the experiments, a computer-controlled multi-channel measuring system and software was developed by the authors. The redox potential measurement method was tested and validated for the determination of coliform bacteria. The results have proved the high efficiency and reliability of the new method.

Area Under Curve↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗