A study on FlexMaster : a Ni-Ti rotary engine driven system for root canal preparation.

Abstract

In the present study, the effectiveness of recently introduced rotary Nickel Titanium FlexMaster engine driven system was evaluated for cleaning and shaping of root canals in extracted human teeth and compared with that done by the Nickel Titanium Flexofile hand instruments. A total of 40 root canals from 36 extracted mandibular and maxillary teeth with curvature ranging between 20 and 30 degree were divided into two groups, consisting 20 canals in each. FlexMaster instrumentation was done in 20 canals, using crown-down technique and manual filing with Flexofile was done in other 20 canals, using conventional and step-back techniques. 5.25% sodium hypochlorite (NaOCl) solution and 17% ethelene di-amine tetra-acetic acid (EDTA) were used alternatively for irrigation after canal preparation by each instrument size. Time needed for canal preparation of individual canal was recorded. A procedural error such as instrument breakage was also noted. After preparation, all the roots were cut longitudinally by using diamond burs in turbine handpiece and examined under scanning electron microscope. Apical region was quantified for debris and smear layer based on a 5-score numerical evaluation scale. The data established for scoring the debris and smear layer and preparation time of individual canal were analyzed statistically using the Mann-Whitney U test. Completely cleaned root canals were not found with any of the two instruments and none of the instruments maintained the original canal uniformity and regular dentine surface. Because significantly less debris was found in the apical region using the manual filing technique (p< 0.05). Thus the flexmaster system was found to produce less cleaner root canal walls than manual technique. Only one FlexMaster finishing file sized 30 was separated in the apical region during preparation of 30 degree curved canal. The time taken by FlexMaster was significantly better (p< 0.01) than that of hand instruments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M S Alam, A K Bashar, J A Begumr, J I Kinoshita. 2006. A study on FlexMaster : a Ni-Ti rotary engine driven system for root canal preparation.. https://doi.org/10.3329/mmj.v15i2.31

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cyclic fatigue of ProTaper instruments.

The present work evaluated the influence of the curved segment length of artificial root canals (the arc) and the number of cycles necessary to fracture engine-driven nickel-titanium endodontic instruments. ProTaper F3 25-mm files at 250 rpm were used in two artificial canals. The artificial canals were made of stainless steel with an inner diameter of 1.04 mm, a total length of 20 mm, and arc on the ends with a radius of curvature of 6 mm. The arc length of the first tube measured 9.4 mm, and the straight part measured 10.6 mm. The second tube was 14.1 mm long, and the straight part measured 5.9 mm. We determined the fracture surface distances and the number of cycles necessary to induce fatigue fracture in the ProTaper F3 instruments. The fracture surfaces and the helical shaft of the instruments were investigated using a scanning electron microscope. The results indicated that the required number of cycles to cause a fracture was influenced by the canal arc length, the morphology of the fractured surface presented ductile characteristics, and plastic deformation in the helical shaft of the fractured instruments did not occur.

Dental High-Speed Equipment↗

The effect of operational speed on the fracture of nickel-titanium rotary instruments.

The purpose of this study was to compare the number of rotations to fracture of nickel-titanium (NiTi) rotary files operated at different speeds and different angles. We used 60 Profile NiTi rotary files, size 25 (30 each of 0.04 and 0.06 taper), operated at speeds of 350 or 600 rpm at angles of 25, 28, and 33.5 degrees. The time to fracture and number of rotations to fracture were recorded and calculated. A significant (p < 0.001) difference was found in the number of rotations to fracture according to taper and angle. Files of 0.06 taper fractured more readily than files of 0.04 taper. Increasing the angle at which the file was rotated decreased the number of rotations to fracture for both tapers; 0.04-taper files were more affected by an increase in the angle than the 0.06-taper files. However, the number of rotations to fracture was not related to the speed at which the files were operated.

Dental High-Speed Equipment↗

Mathematical modeling of flexural behavior of rotary nickel-titanium endodontic instruments.

The aim of the present study was to establish a mathematical model to characterize the flexural behavior of nickel-titanium (NiTi) rotary instruments. The bending behavior of ProFile (0.06 and 0.04 tapers), K-3 (0.06 taper), Quantec (0.04 taper) with tip size of ISO 25, was assessed by pressing the tip of the static rotary file against a smooth, freely movable, glass surface. The deflected instrument was photographed digitally, and the deflection path was digitized in software, to which data a function was fitted that best described the bending behavior of the instrument. It was found that all instruments deflected in a manner closely resembling a negative exponential function: y = A x e(-x/b). The present approach indicated that the analytical difficulties of handling the complex cross-section in tapering spirals in beam-bending theory may be circumvented by a practical and elementary curve-fitting method.