PubMed Health⌕ Search

PubMed · 16901913

Nerve excitability changes in critical illness polyneuropathy.

Abstract

Patients in intensive care units frequently suffer muscle weakness and atrophy due to critical illness polyneuropathy (CIP), an axonal neuropathy associated with systemic inflammatory response syndrome and multiple organ failure. CIP is a frequent and serious complication of intensive care that delays weaning from mechanical ventilation and increases mortality. The pathogenesis of CIP is not well understood and no specific therapy is available. The aim of this project was to use nerve excitability testing to investigate the changes in axonal membrane properties occurring in CIP. Ten patients (aged 37-76 years; 7 males, 3 females) were studied with electrophysiologically proven CIP. The median nerve was stimulated at the wrist and compound action potentials were recorded from abductor pollicis brevis muscle. Strength-duration time constant, threshold electrotonus, current-threshold relationship and recovery cycle (refractoriness, superexcitability and late subexcitability) were recorded using a recently described protocol. In eight patients a follow-up investigation was performed. All patients underwent clinical examination and laboratory investigations. Compared with age-matched normal controls (20 subjects; aged 38-79 years; 7 males, 13 females), CIP patients exhibited reduced superexcitability at 7 ms, from -22.3 +/- 1.6% to -7.6 +/- 3.1% (mean +/- SE, P approximately 0.0001) and increased accommodation to depolarizing (P < 0.01) and hyperpolarizing currents (P < 0.01), indicating membrane depolarization. Superexcitability was reduced both in patients with renal failure and without renal failure. In the former, superexcitability correlated with serum potassium (R = 0.88), and late subexcitability was also reduced (as also occurs owing to hyperkalaemia in patients with chronic renal failure). In patients without renal failure, late subexcitability was normal, and the signs of membrane depolarization correlated with raised serum bicarbonate and base excess, indicating compensated respiratory acidosis. It is inferred that motor axons in these CIP patients are depolarized, in part because of raised extracellular potassium, and in part because of hypoperfusion. The chronic membrane depolarization may contribute to the development of neuropathy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W J Z'Graggen, C S Y Lin, R S Howard, R J Beale, H Bostock. 2006-08-10. Nerve excitability changes in critical illness polyneuropathy.. https://doi.org/10.1093/brain%2Fawl191

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perioperative extracorporeal membrane oxygenation support for critical pediatric airway surgery.

Extracorporeal membrane oxygenation (ECMO) has been used for cardiopulmonary support in neonates, infants, and adults. We report the application of ECMO for critical airway surgery when mechanical ventilation cannot provide adequate gas exchange. Three pediatric patients underwent emergency ECMO establishment because of hypercapnia that could not be managed by conventional mechanical ventilation. The pathology included: (1) left pulmonary artery sling with long-segment tracheal stenosis; (2) absence of the right intermediate bronchus and abnormal origin of the right lower bronchus arising from the left main bronchus; (3) right-lung agenesis with long-segment tracheobronchial stenosis. Venoarterial ECMO was established. Before ECMO, the arterial pH values were 7.28, 7.0, and 7.08, and the PaCO2 values were 111.8, 112.0, and 208.7 mmHg for each patient, respectively. After ECMO support, respiratory acidosis was reversed. The patients then underwent surgical intervention. The surgical procedures included: (1) slide tracheoplasty and reimplantation of the left pulmonary artery; (2) resection of the stenotic tracheal segment and reconstruction of the bronchial tree; (3) tracheal dilatation and stent implantation. The ECMO durations were 11, 5, and 16 h, respectively. All patients were successfully weaned off ECMO without complications. In conclusion, ECMO provided adequate ventilation support for patients undergoing critical tracheobronchial reconstruction when conventional mechanical ventilation could not maintain adequate gas exchange.

Acidosis, Respiratory↗

Extracorporeal carbon dioxide removal using the Novalung in a patient with intracranial bleeding.

A neurosurgical patient who required repeated surgery for intracranial haematoma developed acute respiratory distress syndrome. Raised intracranial pressure proved difficult to manage whilst attempting to maintain optimal gas exchange. The resultant arterial partial pressure of carbon dioxide remained unacceptably high, and treatment by extracorporeal carbon dioxide removal was started. A pumpless arteriovenous interventional lung assist device (Novalung) was connected from the right femoral artery to left femoral vein and reduced the arterial carbon dioxide, corrected the respiratory acidosis and enabled control of the intracranial pressure. Subsequently the requirements for both respiratory and cardiovascular support were reduced. The patient made a complete neurological recovery.

Acidosis, Respiratory↗

Renal compensation to chronic hypoxic hypercapnia: downregulation of pendrin and adaptation of the proximal tubule.

The molecular basis for the renal compensation to respiratory acidosis and specifically the role of pendrin in this condition are unclear. Therefore, we studied the adaptation of the proximal tubule and the collecting duct to respiratory acidosis. Male Wistar-Hannover rats were exposed to either hypercapnia and hypoxia [8% CO(2) and 13% O(2) (hypercapnic, n = 6) or normal air (controls, n = 6)] in an environmental chamber for 10 days and were killed under the same atmosphere. In hypercapnic rats, arterial pH was lower than controls (7.31 +/- 0.01 vs. 7.39 +/- 0.01, P = 0.03), blood HCO(3)(-) concentration was increased (42 +/- 0.9 vs. 32 +/- 0.24 mM, P < 0.001), arterial Pco(2) was increased (10.76 +/- 0.4 vs. 7.20 +/- 0.4 kPa, P < 0.001), and plasma chloride concentration was decreased (92.2 +/- 0.7 vs. 97.2 +/- 0.5 mM, P < 0.001). Plasma aldosterone levels were unchanged. In the proximal tubule, immunoblotting showed an increased expression of sodium/bicarbonate exchanger protein (188 +/- 22 vs. 100 +/- 11%, P = 0.005), confirmed by immunohistochemistry. Total Na/H exchanger protein expression in the cortex was unchanged by immunoblotting (119 +/- 10 vs. 100 +/- 11%, P = 0.27) and immunohistochemistry. In the cortex, the abundance of pendrin was decreased (51 +/- 9 vs. 100 +/- 7%, P = 0.003) by immunoblotting. Immunohistochemistry revealed that this decrease was clear in both cortical collecting ducts (CCDs) and connecting tubules (CNTs). This demonstrates that pendrin expression can be regulated in acidotic animals with no changes in aldosterone levels and no external chloride load. This reduction of pendrin expression may help in redirecting the CNT and CCD toward chloride excretion and bicarbonate reabsorption, contributing to the increased plasma bicarbonate and decreased plasma chloride of chronic respiratory acidosis.

Acidosis, Respiratory↗