PubMed Health⌕ Search

PubMed · 16920141

Implications of methodological differences in digital electrocardiogram interval measurement.

Abstract

Well-specified recommendations have yet to be established on how electrocardiogram (ECG) interval measurement should be performed by digital on-screen caliper systems to assess drug-induced effect on cardiac repolarization in pharmaceutical clinical trials with adequate precision and reproducibility. Since 1997, the industry has followed the European Committee for Proprietary Medicinal Products Points to Consider by using fully manual measurement of 3 consecutive sinus rhythm PQRST complexes in 1 lead only (typically limb lead II). More recently, semiautomatic measurement performed on representative (median) beats and based on the global leads has been considered. The International Conference on Harmonization E14 guidance (June 2005) advocates development of quality standards for centralized ECG interval measurement and allows all methods "whether or not assisted by computer" but includes no recommendations on how to perform the measurement. We provide an overview of the currently available methods for digital ECG interval measurement and the implications of between-method differences on quality of ECG interval measurements. We applied 4 methods most commonly used to assess QT prolongation (applied on 3 raw beats in limb lead II or by global measurement on 1 or 12 superimposed representative beats). QT, QTc Fridericia, and RR interval durations were measured on resting 12-lead digital ECGs obtained in 26 healthy volunteers predose and at 1, 2, and 3 hours after dosing with a single 160 mg oral dose of sotalol. Absolute interval durations and changes from baseline were compared between the 4 measurement methods. A better understanding of the implications from different measurement methodologies will facilitate more informed choice of the appropriate method for ECG interval measurement on clinical trials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fabio Badilini, Nenad Sarapa. 2006-08-21. Implications of methodological differences in digital electrocardiogram interval measurement.. https://doi.org/10.1016/j.jelectrocard.2006.05.030

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A note on a generalized single step theory for any number of hierarchical genomic matrices.

BACKGROUND: The Single Step algorithm allows combining information from genotyped and un-genotyped individuals, provided they are connected by a pedigree. However, current single step theory is limited to a single list of markers. RESULTS: We present a generalized single step (GSS) method that can accommodate any number of hierarchical molecular datasets (e.g. sequence, high and low density arrays) and pedigree, avoiding imputation. We prove that a similar efficient inversion algorithm exists. The method is recursive, starting with the highest marker density scenario. We illustrate the method with simulation and show that GSS can increase predictive accuracy compared to standard single step. R code is provided so that custom scenarios can be easily compared, either with simulated or real data. CONCLUSION: The method developed generalizes extant single step theory to any number of hierarchical molecular relationship matrices, broadening the scenarios where single step can be applied. A topic of particular interest can be ecology field data or human populations where pedigree is not available, but where samples sequenced and genotyped at different densities can exist. GSS can also be a useful tool to optimize allocation of genotyping and / or sequencing resources.

Algorithms↗

cgDist: Nucleotide-level distance calculation from cgMLST allelic profiles.

Bacterial genomic surveillance requires balancing computational efficiency with genetic resolution for effective cluster investigation. cgMLST distance calculations treat all allelic differences as equivalent units, obscuring nucleotide-level variation. Furthermore, single nucleotide polymorphism-based pipelines provide finer resolution at substantially higher computational cost, which limits their routine deployment in surveillance laboratories. We present cgDist, an algorithm that calculates nucleotide-level distances directly from cgMLST allelic profiles, providing finer resolution than allele-count distances by leveraging within-allele nucleotide variation. The cache architecture stores alignment statistics, enabling distance calculation modes without computation and supporting both dataset-specific and schema-complete cache generation. This design enables incremental surveillance analysis, with performance benefits as laboratories accumulate alignment data. cgDist functions as a precision 'zoom lens' for the investigation of clusters identified through initial cgMLST screening. Rather than restructuring population relationships, this targeted approach concentrates enhanced resolution where it is most informative. The algorithm ensures that cgDist distances are greater than or equal to corresponding cgMLST distances, preserving epidemiological interpretability while adding genetic discrimination. By increasing resolution within identified clusters, cgDist may also support outbreak investigation, a potential application that remains to be evaluated on outbreak-derived data.

Algorithms↗

Theseus: fast and optimal affine-gap sequence-to-graph alignment.

MOTIVATION: Sequence-to-graph alignment is a central problem in bioinformatics, with applications in multiple sequence alignment (MSA) and pangenome analysis, among others. However, current algorithms for optimal affine-gap alignment impose high memory and computational requirements, limiting their scalability to aligning long sequences to complex graphs. Practical solutions partially address this problem using heuristic strategies that ultimately trade off optimality for speed. RESULTS: This work presents Theseus, a novel, fast, and optimal affine-gap sequence-to-graph alignment algorithm. Theseus leverages similarities between genomic sequences to accelerate the alignment computation and reduces the overall memory requirements without compromising optimality. To that end, Theseus processes only a subset of the dynamic programming cells, using a sparse-data strategy that enables efficient sequence-to-graph alignment. Moreover, our algorithm supports optimal affine-gap alignment on arbitrary directed graphs, including those with cycles. We evaluate Theseus on two key problems: MSA and pangenome read mapping. For MSA, we compare it against SPOA, abPOA, and POASTA. Theseus is 1.6× to 17.6× faster than POASTA, and 7.3× faster, on average, than SPOA, both optimal aligners. Compared with abPOA, Theseus ensures optimality and scales to the largest problems. For pangenome read mapping, we benchmark Theseus against the alignment stage of the mapping tool vg map, along with the alignment kernels of SPOA, abPOA, and POASTA. Theseus outperforms the other methods, showing a 1.9× to 16.9× speedup on short reads. Moreover, Theseus is 1.5× to 36.3× faster than vg when aligning against synthetic cyclic graphs. AVAILABILITY AND IMPLEMENTATION: Theseus code and documentation are publicly available at https://github.com/albertjimenezbl/theseus-lib.

Algorithms↗