PubMed Health⌕ Search

PubMed · 16934906

Developing and validating a diabetes database in a large health system.

Abstract

BACKGROUND: One component of clinical information systems is a registry of patients. Registries allow providers to identify gaps in care at the population level. Registries also allow for rapid cycle continuous quality improvement, targeted practice change and improved outcomes. Most registries are built based on membership with an insurer or other selection criteria. Little, if any data exist on registries representing demographically heterogeneous populations. METHODS: Administrative and clinical data for the period 1/1/2000-12/30/03 were examined. In total, 46,082,941 lab reports, 233,292,544 medical records, and 9,351,415 medical record abstracts, representing approximately 2 million unique patients were searched. The diabetes source population was identified by presence of any one of the following criteria: ICD-9 code 250 (diabetes) for inpatient, emergency room or outpatient visits; any hemoglobin A1c result; blood glucose >200mg/dl; or diabetes medication. A diagnosis of diabetes was verified by trained chart reviewers on a sample of patients. Single indicators and combinations were examined to determine optimal identification of these cases. RESULTS: In two separate validation studies, using two or more indicators or outpatient diagnosis maximized positive predictive value (PPV) (96 and 97%) and sensitivity (99 and 100%) and identified 55,807 individuals. When all patients with a single indicator of outpatient diagnosis (which had the highest single PPV of 94 and 95%) were included together with those having >or=2 indicators, the final sample size was 65,725. CONCLUSION: Two or more indicators or an out-patient-diagnosis identifies a sizeable and unselective diabetes database which can be used to track processes and outcomes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Janice C Zgibor, Trevor J Orchard, Melissa Saul, Gretchen Piatt, Kristine Ruppert, Andrew Stewart, Linda M Siminerio. 2006-08-28. Developing and validating a diabetes database in a large health system.. https://doi.org/10.1016/j.diabres.2006.07.007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance of the FearID earprint identification system.

The Forensic Ear Identification (FearID) research project was started in order to study the strength of evidence of earprints found on crime scenes. For this purpose, a sample of earprints from 1229 donors over three countries was collected. From each donor three left and three right earprints were gathered. On the one hand, operators denoted contours of the earprints to facilitate segmentation of the images, on the other anthropological specialists denoted anatomically specific locations. On the basis of this, methods for automated classification were developed and used for training of a system that classifies pairs of prints as 'matching' or 'non-matching'. Comparing lab quality prints, the system has an equal error rate of 4%. Starting from a reference database containing two prints per ear, hitlist behaviour is such that in 90% of all query searches the best hit is in the top 0.1% of the list. The results become less favourable (equal error rate of 9%) for print/mark comparisons.

Databases, Factual↗

Normal limits of ejection fraction and volumes determined by gated SPECT in clinically normal patients without cardiac events: a study based on the J-ACCESS database.

PURPOSE: Quantitative gated single-photon emission computed tomography (SPECT) is known to have high accuracy and precision for measurement of the principal cardiac functional parameters. We hypothesised that normal values for EF and LV volumes may differ among nationalities, and that optimal threshold values specific to the study population are required. METHODS: Among 4,670 consecutively registered patients for a J-ACCESS (Japanese investigation regarding prognosis based on gated SPECT) study from 117 hospitals, a total of 268 (149 women, 119 men) were selected who had no baseline cardiac diseases and had experienced no cardiac events during the preceding 3-year period. A gated SPECT study was performed with 99mTc-tetrofosmin and analysed with Cedars Sinai Medical Center's quantitative gated SPECT (QGS) software. The results in respect of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) and stroke volume (SV), and EDV, ESV and SV normalised by body surface area (EDVI, ESVI and SVI), were calculated and summarised to obtain normal limits. RESULTS: EF for women and men was 74 +/- 9% and 63 +/- 7%, respectively (p < 0.0001). EDV, ESV and SV were significantly smaller in women than in men. Based on multiple regressions for linear models, the primary and secondary predictors of EF, EDVI, ESVI were gender and age. By stepwise multiple regression analysis, a statistically significant third predictor for EDV, ESV, SV and SVI was body weight. No colinearity was found between age and body weight. Important factors for the studied Japanese population included a high incidence of small hearts in women and the relatively advanced age of the population (the mean age +/-SD was 64.1 +/- 10.0 years for women and 60.9 +/- 11.7 years for men). CONCLUSION: EF and volumes determined by gated SPECT with QGS were significantly affected by gender and age, with body weight as a third predictor for volumes. Moreover, the normal limits were so specific for the population studied that standards appropriate for the study in question should be utilised.

Databases, Factual↗