PubMed Health⌕ Search

PubMed · 16955261

Single-cell manipulation and analysis using microfluidic devices.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gregory T Roman, Yanli Chen, Pernilla Viberg, Anne H Culbertson, Christopher T Culbertson. 2007. Single-cell manipulation and analysis using microfluidic devices.. https://doi.org/10.1007/s00216-006-0670-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Study of on-line monitoring of lactate based on optical fibre sensor and in-channel mixing mechanism.

A PDMS-based microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The detection is based on the optical adsorption of the colour solution formed by in-channel mixing of sample and reagent solutions. Computational Fluid Dynamics (CFD) simulation and kinetic study of the colour development were conducted to determine the minimum channel length and optimum residential time for homogenous mixing and maximum optical adsorption respectively. The system was proved to be able to detect lactate with good linearity (R(2)=0.98), response time of about 130 s and estimated limitation of detection (LOD) of 0.52 mM (about 47 mg/L), which is sufficient for a general online lactate detection. Due to the miniaturization of sensing system and micro-scale mixing, higher detection sensitivity (0.15 V/mM) can be realized than the mixing in lab-scale equipments (0.08 V/mM).

Dimethylpolysiloxanes↗

Glass-fiber reinforced poly(acrylate)-based sorptive materials for the enrichment of organic micropollutants from aqueous samples.

A novel and simple approach to sorptive materials for the extraction of organic compounds from environmental samples is presented. It entails the use of glass fiber fabric strips coated with a customized poly(acrylate) (PA) formulation as extraction medium. Analytes were enriched by means of shaking of the PA strip in the sample and then subsequently thermally desorbed and analyzed by GC-MS. The performance of the sorptive materials was evaluated by the enrichment of compounds with different polarities (phenols, hexachlorobenzene and hexachlorocyclohexanes) from water samples. Parameters that affect the extraction process such as pH, ionic strength of the solvent, mixing mechanism, extraction time and desorption conditions were investigated. The extraction abilities of the PA extraction medium were compared with that of commercially available poly(dimethylsiloxane) (PDMS) Twisters. The results revealed that the new material shows higher affinity for phenolic compounds presumably due to the presence of polar groups. The partition coefficients for the PA strips estimated in this work were up to 15 times higher than for the PDMS Twister, resulting in higher recoveries and lower detection limits. The method was applied for the quantification of the aforementioned compounds in contaminated surface water samples from Bitterfeld (Germany). Using both PA strips and PDMS Twisters, good agreement of the extraction data was achieved.

Dimethylpolysiloxanes↗

Microfluidic serial dilution circuit.

In vitro evolution of RNA molecules requires a method for executing many consecutive serial dilutions. To solve this problem, a microfluidic circuit has been fabricated in a three-layer glass-PDMS-glass device. The 400-nL serial dilution circuit contains five integrated membrane valves: three two-way valves arranged in a loop to drive cyclic mixing of the diluent and carryover, and two bus valves to control fluidic access to the circuit through input and output channels. By varying the valve placement in the circuit, carryover fractions from 0.04 to 0.2 were obtained. Each dilution process, which is composed of a diluent flush cycle followed by a mixing cycle, is carried out with no pipeting, and a sample volume of 400 nL is sufficient for conducting an arbitrary number of serial dilutions. Mixing is precisely controlled by changing the cyclic pumping rate, with a minimum mixing time of 22 s. This microfluidic circuit is generally applicable for integrating automated serial dilution and sample preparation in almost any microfluidic architecture.

Dimethylpolysiloxanes↗