A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate.

Abstract

Disposable microsensors on polymer substrates consisting of fully integrated on-chip planar cobalt (Co) microelectrodes, Ag/AgCl reference electrodes, and microfluidic channels have been designed, fabricated, and characterized for phosphate concentration measurement in aqueous solution. The planar Co microelectrode shows phosphate-selective potential response over the range from 10(-5) to 10(-2)M in acidic medium (pH 5.0) for both inorganic (KH(2)PO(4)) and organic (adenosine 5'-triphosphate (ATP) and adenosine 5'-diphosphates (ADP)) phosphate compounds. This microfabricated sensor also demonstrates significant reproducibility with a small repeated sensing deviation (i.e. relative standard deviation (R.S.D.)<1%) on a single chip and a small chip-to-chip deviation (i.e. R.S.D.<2.5%). Specifically, while keeping the high selectivity, sensitivity, and stability of a conventional bulk Co-wire electrode, the proposed phosphate sensor yields advantages such as ease of use, cost effectiveness, reduced analyte consumption, and ease of integrating into disposable polymer lab-on-a-chip devices. The capability to sense both inorganic and organic phosphate compounds makes this sensor applicable in diverse areas such as environmental monitoring, soil extract analysis, and clinical diagnostics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhiwei Zou, Jungyoup Han, Am Jang, Paul L Bishop, Chong H Ahn. 2006-09-18. A disposable on-chip phosphate sensor with planar cobalt microelectrodes on polymer substrate.. https://doi.org/10.1016/j.bios.2006.08.004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-&#x3b3; and TNF-&#x3b1;), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques↗

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine&#x2011;hydrogen peroxide (TMB-H&#x2082;O&#x2082;) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82&#xa0;CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques↗

Investigating the molecular mechanisms of in-plane mechanochemistry on cantilever arrays.

Free-standing cantilevers, which directly translate specific biochemical reactions into micromechanical motion, have recently attracted much attention as label-free biosensors and micro/nano robotic devices. To exploit this mechanochemical sensing technology, it is essential to develop a fundamental understanding of the origins of surface stress. Here we report a detailed study into the molecular basis of stress generation in aqueous environments focusing on the pH titration of model mercaptohexadecanoic acid self-assembled monolayers (SAMs), using in situ reference cantilevers coated with nonionizable hexadecanethiol SAMs. Semiautomated data analysis and a statistical model were developed to quantify cyclic deprotonation/protonation reactions on multiple arrays. In-plane force titrations were found to have the sensitivity to detect ionic hydrogen bond formation between protonated and nonprotonated carboxylic acid groups in the proximity of the surface pK1/2, which generated a mean tensile differential surface stress of +1.2 +/- 0.3 mN/m at pH 6.0, corresponding to 1 pN attractive force between two adjacent MHA molecules. Conversely, the magnitude of compressive differential surface stress was found to increase progressively with pH >/= 7.0, reaching a maximum of -14.5 +/- 0.5 mN/m at pH 9.0, attributed to enhanced electrostatic repulsion between deprotonated carboxylic acid groups. However, striking differences were observed in the micromechanical responses to different ionic strength and ion species present in the aqueous environment, highlighting the critical role of counter- and co-ions on surface stress. Our findings provide fundamental insights into the molecular mechanisms of in-plane mechanochemistry, which may be exploited for biosensing and nanoactuation applications.

Biosensing Techniques↗