PubMed · 17001005
Deterministic hydrodynamics: taking blood apart.
Abstract
We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic size, independent of their mass. We use the technology we developed of deterministic arrays which separate white blood cells, red blood cells, and platelets from blood plasma at flow velocities of 1,000 microm/sec and volume rates up to 1 microl/min. We verified by flow cytometry that an array using focused injection removed 100% of the lymphocytes and monocytes from the main red blood cell and platelet stream. Using a second design, we demonstrated the separation of blood plasma from the blood cells (white, red, and platelets) with virtually no dilution of the plasma and no cellular contamination of the plasma.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
John A Davis, David W Inglis, Keith J Morton, David A Lawrence, Lotien R Huang, Stephen Y Chou, James C Sturm, Robert H Austin. 2006-09-25. Deterministic hydrodynamics: taking blood apart.. https://doi.org/10.1073/pnas.0605967103. https://pubmed.health/record/pubmed%3A17001005/deterministic-hydrodynamics-taking-blood-apart
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.