PubMed Health⌕ Search

Biomedical subjects

Robert H Austin

Publications and source records attributed to Robert H Austin.

At least 19 recordsLinked to original sources

Bacterial metapopulations in nanofabricated landscapes.

We have constructed a linear array of coupled, microscale patches of habitat. When bacteria are inoculated into this habitat landscape, a metapopulation emerges. Local bacterial populations in each patch coexist and weakly couple with neighbor populations in nearby patches. These spatially distributed bacterial populations interact through local extinction and colonization processes. We have further built heterogeneous habitat landscapes to study the adaptive dynamics of the bacterial metapopulations. By patterning habitat differences across the landscape, our device physically implements an adaptive landscape. In landscapes with higher niche diversity, we observe rapid adaptation to large-scale, low-quality (high-stress) areas. Our results illustrate the potential lying at the interface between nanoscale biophysics and landscape evolutionary ecology.

Adaptation, Biological↗

Deterministic hydrodynamics: taking blood apart.

We show the fractionation of whole blood components and isolation of blood plasma with no dilution by using a continuous-flow deterministic array that separates blood components by their hydrodynamic size, independent of their mass. We use the technology we developed of deterministic arrays which separate white blood cells, red blood cells, and platelets from blood plasma at flow velocities of 1,000 microm/sec and volume rates up to 1 microl/min. We verified by flow cytometry that an array using focused injection removed 100% of the lymphocytes and monocytes from the main red blood cell and platelet stream. Using a second design, we demonstrated the separation of blood plasma from the blood cells (white, red, and platelets) with virtually no dilution of the plasma and no cellular contamination of the plasma.

Blood Platelets↗

Wetting micro- and nanofluidic devices using supercritical water.

We describe a method for wetting micro- and nanofluidic devices with water or any other pure liquid. The process is performed by enclosing the fluidic device in a liquid-filled cell, heating the cell to a temperature above the critical point of the liquid, and subsequent cooling of the cell to room temperature. Because the process liquid is essentially a gas during wetting, arbitrary shapes can be wetted. We demonstrate wetting of micro- and nanostructures in a fused-silica device with only a single inlet. The process is low-cost, fast, safe, and very reliable.

Microfluidic Analytical Techniques↗

Single molecule measurements of repressor protein 1D diffusion on DNA.

We used single-molecule imaging techniques and measured the one-dimensional diffusion of LacI repressor proteins along elongated DNA to address the long-standing puzzle of why some proteins find their targets faster than allowed by 3D diffusion. Our analysis of the LacI transcription factor's diffusion yielded four main results: (1) LacI diffuses along nonspecific sequences of DNA in the form of 1D Brownian motion; (2) the observed 1D diffusion coefficients D1vary over an unexpectedly large range, from 2.3x10(-12) cm2/s to 1.3x10(-9) cm2/s; (3) the lengths of DNA covered by these 1D diffusions vary from 120 nm to 2920 nm; and (4) the mean values of D1 and the diffusional lengths indeed predict a LacI target binding rate 90 times faster than the 3D diffusion limit.

Bacterial Proteins↗

Critical particle size for fractionation by deterministic lateral displacement.

The fractionation of small particles in a liquid based on their size in a micropost array by deterministic lateral displacement was recently demonstrated with unprecedented resolution (L. R. Huang, E. C. Cox, R. H. Austin and J. C. Sturm, Science, 2004, 304, 987-990, ). In this paper, we present a model of how the critical particle size for fractionation depends on the micropost geometry, depending specifically on the gap between posts, the offset of posts in one row with respect to another, and whether the fluid is driven by hydrodynamics or by electroosmosis. In general the critical particle diameter is much smaller than the gap, which prevents clogging. The model is supported by data with particles from 2.3 to 22 microm.

Chemical Fractionation↗

In vivo and scanning electron microscopy imaging of up-converting nanophosphors in Caenorhabditis elegans.

We show here that upconversion phosphors can be imaged both by infrared excitation and in a scanning electron microscope. We have synthesized and characterized for this work up-converting phosphor nanoparticles nonaggregated nanocrystals of size range 50-200 nm. We have investigated the optical properties of 50-200 nm nanoparticles and found a square dependence of the emitted visible fluorescence on the infrared excitation and verified that under electron excitation similar narrow band emission spectra can be obtained as is seen with IR upconversion. The viability of the nanoparticles for biological imaging was confirmed by imaging the digestive system of the nematode worm Caenorhabditis elegans, and we have confirmed using energy-dispersive X-ray analysis that the up-conversion nanoparticles can be identified in a scanning electron microscope at high spatial resolution.

Animals↗

A nanofluidic railroad switch for DNA.

We present a metamaterial consisting of a two-dimensional, asymmetric lattice of crossed nanochannels in fused silica, with channel diameters of 80 nm to 140 nm. When DNA is introduced, it is stretched and linearized. We show that the asymmetry in channel dimensions gives rise to a preferred direction for DNA orientation and a preferred direction for transport under dc electrophoresis. Interestingly, the preferred axis of orientation and transport can be switched by 90 degrees through application of an ac voltage. We explain the results in terms of an energy landscape for polyelectrolytes that consists of entropic and dielectrophoretic contributions and whose strength and sign can be tuned by changing the ac field strength.

DNA↗

Restriction mapping in nanofluidic devices.

We have performed restriction mapping of DNA molecules using restriction endonucleases in nanochannels with diameters of 100-200 nm. The location of the restriction reaction within the device is controlled by electrophoresis and diffusion of Mg2+ and EDTA. We have successfully used the restriction enzymes SmaI, SacI, and PacI, and have been able to measure the positions of restriction sites with a precision of approximately 1.5 kbp in 1 min using single DNA molecules.

DNA↗

Single-molecule studies of repressor-DNA interactions show long-range interactions.

We have performed single-molecule studies of GFP-LacI repressor proteins bound to bacteriophage lambda DNA containing a 256 tandem lac operator insertion confined in nanochannels. An integrated photon molecular counting method was developed to determine the number of proteins bound to DNA. By using this method, we determined the saturated mean occupancy of the 256 tandem lac operators to be 13, which constitutes only 2.5% of the available sites. This low occupancy level suggests that the repressors influence each other even when they are widely separated, at distances on the order of 200 nm, or several DNA persistence lengths.

Bacteriophage lambda↗

Statics and dynamics of single DNA molecules confined in nanochannels.

The successful design of nanofluidic devices for the manipulation of biopolymers requires an understanding of how the predictions of soft condensed matter physics scale with device dimensions. Here we present measurements of DNA extended in nanochannels and show that below a critical width roughly twice the persistence length there is a crossover in the polymer physics.

Bacteriophage lambda↗

Picosecond thermometer in the amide I band of myoglobin.

The amide I and II bands in myoglobin show a heterogeneous temperature dependence, with bands at 6.17 and 6.43 microm which are more intense at low temperatures. The amide I band temperature dependence is on the long wavelength edge of the band, while the short wavelength side has almost no temperature dependence. We compare concepts of anharmonic solid-state crystal physics and chemical physics for the origins of these bands. We suggest that the long wavelength side is composed of those amino acids which hydrogen bond to the hydration shell of the protein, and that temperature dependent bands can be used to determine the time it takes vibrational energy to flow into the hydration shell. We determine that vibrational energy flow to the hydration shell from the amide I takes approximately 20 ps to occur.

Amides↗

Force mapping in epithelial cell migration.

We measure dynamic traction forces exerted by epithelial cells on a substrate. The force sensor is a high-density array of elastomeric microfabricated pillars that support the cells. Traction forces induced by cell migration are deduced from the measurement of the bending of these pillars and are correlated with actin localization by fluorescence microscopy. We use a multiple-particle tracking method to estimate the mechanical activity of cells in real time with a high-spatial resolution (down to 2 microm) imposed by the periodicity of the post array. For these experiments, we use differentiated Madin-Darby canine kidney (MDCK) epithelial cells. Our data provide definite information on mechanical forces exerted by a cellular assembly. The maximum intensity of the forces is localized on the edge of the epithelia. Hepatocyte growth factor promotes cell motility and induces strong scattering activity of MDCK cells. Thus, we compare forces generated by MDCK cells in subconfluent epithelia versus isolated cells after hepatocyte growth factor treatment. Maximal-traction stresses at the edge of a monolayer correspond to higher values than those measured for a single cell and may be due to a collective behavior.

Actins↗

From the Cover: The dynamics of genomic-length DNA molecules in 100-nm channels.

We show that genomic-length DNA molecules imaged in nanochannels have an extension along the channel that scales linearly with the contour length of the polymer, in agreement with the scaling arguments developed by de Gennes for self-avoiding confined polymers. This fundamental relationship allows us to measure directly the contour length of single DNA molecules confined in the channels, and the statistical analysis of the dynamics of the polymer in the nanochannel allows us to compute the SD of the mean of the extension. This statistical analysis allows us to measure the extension of lambda DNA multimers with a 130-nm SD in 1 min.

DNA↗

Continuous particle separation through deterministic lateral displacement.

We report on a microfluidic particle-separation device that makes use of the asymmetric bifurcation of laminar flow around obstacles. A particle chooses its path deterministically on the basis of its size. All particles of a given size follow equivalent migration paths, leading to high resolution. The microspheres of 0.8, 0.9, and 1.0 micrometers that were used to characterize the device were sorted in 40 seconds with a resolution of approximately 10 nanometers, which was better than the time and resolution of conventional flow techniques. Bacterial artificial chromosomes could be separated in 10 minutes with a resolution of approximately 12%.

Chemical Fractionation↗

Micro- and nanofluidics for DNA analysis.

Miniaturization to the micrometer and nanometer scale opens up the possibility to probe biology on a length scale where fundamental biological processes take place, such as the epigenetic and genetic control of single cells. To study single cells the necessary devices need to be integrated on a single chip; and, to access the relevant length scales, the devices need to be designed with feature sizes of a few nanometers up to several micrometers. We will give a few examples from the literature and from our own research in the field of miniaturized chip-based devices for DNA analysis, including dielectrophoresis for purification of DNA, artificial gel structures for rapid DNA separation, and nanofluidic channels for direct visualization of single DNA molecules.

Cell Separation↗

Tilted brownian ratchet for DNA analysis.

In this paper, we report a factor of 3 improvement in the resolution and a factor of 10 improvement in the speed of fractionation of approximately 100-kb DNA molecules in Brownian ratchet arrays. In our device, the electrophoretic flow is tilted at a small angle relative to the array axis. Tilting accelerates the fractionation speed because a higher fraction of the diffusing molecules is "ratcheted" at each step in the array. Molecules of lengths 48.5 and 164 kb can be separated in approximately 70 min with a resolution of approximately 3.8, using a 12-mm-long array. The Brownian ratchet arrays are not limited to DNA separation, but can, in principle, be used for any particle in this size range.

Chemical Phenomena↗

Of spherical cows, cloudy crystal balls, and proteins.

Although proteins perform a vast multitude of tasks in living organisms, perhaps the most fascinating and least well understood is the nanoengine aspect of protein action, where chemical energy is turned into mechanical motion. In order for this to happen a protein must change chemical bond energy into physical displacement via some sort of a conformational change of the protein. The critical first step of this process must be the transient storage (self-trapping) of chemical energy into some metastable strained conformation of the protein. We discuss how the early work of Irwin C. "Gunny" Gunsalus with Hans Frauenfelder and Peter Debrunner led to insights into the picosecond dynamics of proteins, the initial functionally important motions.

Crystallography↗