High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings.

Abstract

A general-purpose high frame rate (HFR) medical imaging system has been developed. This system has 128 independent linear transmitters, each of which is capable of producing an arbitrary broadband (about 0.05-10 MHz) waveform of up to +/- 144 V peak voltage on a 75-ohm resistive load using a 12-bit/40-MHz digital-to-analog converter. The system also has 128 independent, broadband (about 0.25-10 MHz), and time-variable-gain receiver channels, each of which has a 12-bit/40-MHz analog-to-digital converter and up to 512 MB of memory. The system is controlled by a personal computer (PC), and radio frequency echo data of each channel are transferred to the same PC via a standard USB 2.0 port for image reconstructions. Using the HFR imaging system, we have developed a new limited-diffraction array beam imaging method with square-wave aperture voltage weightings. With this method, in principle, only one or two transmitters are required to excite a fully populated two-dimensional (2-D) array transducer to achieve an equivalent dynamic focusing in both transmission and reception to reconstruct a high-quality three-dimensional image without the need of the time delays of traditional beam focusing and steering, potentially simplifying the transmitter subsystem of an imager. To validate the method, for simplicity, 2-D imaging experiments were performed using the system. In the in vitro experiment, a custom-made, 128-element, 0.32-mm pitch, 3.5-MHz center frequency linear array transducer with about 50% fractional bandwidth was used to reconstruct images of an ATS 539 tissue-mimicking phantom at an axial distance of 130 mm with a field of view of more than 90 degrees. In the in vivo experiment of a human heart, images with a field of view of more than 90 degrees at 120-mm axial distance were obtained with a 128-element, 2.5-MHz center frequency, 0.15-mm pitch Acuson V2 phased array. To ensure that the system was operated under the limits set by the U.S. Food and Drug Administration, the mechanical index, thermal index, and acoustic output were measured. Results show that higher-quality images can be reconstructed with the square-wave aperture weighting method due to an increased penetration depth as compared to the exact weighting method developed previously, and a frame rate of 486 per second was achieved at a pulse repetition frequency of about 5348 Hz for the human heart.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jian-Yu Lu, Jiqi Cheng, Jing Wang. 2006. High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings.. https://doi.org/10.1109/tuffc.2006.112

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗