Bone density testing in clinical practice.

Abstract

The diagnosis of osteoporosis and monitoring of treatment is a challenge for physicians due to the large number of available tests and complexities of interpretation. Bone mineral density (BMD) testing is a non-invasive measurement to assess skeletal health. The "gold-standard" technology for diagnosis and monitoring is dual-energy X-ray absorptiometry (DXA) of the spine, hip, or forearm. Fracture risk can be predicted using DXA and other technologies at many skeletal sites. Despite guidelines for selecting patients for BMD testing and identifying those most likely to benefit from treatment, many patients are not being tested or receiving therapy. Even patients with very high risk of fracture, such as those on long-term glucocorticoid therapy or with prevalent fragility fractures, are often not managed appropriately. The optimal testing strategy varies according to local availability and affordability of BMD testing. The role of BMD testing to monitor therapy is still being defined, and interpretation of serial studies requires special attention to instrument calibration, acquisition technique, analysis, and precision assessment. BMD is usually reported as a T-score, the standard deviation variance of the patient's BMD compared to a normal young-adult reference population. BMD in postmenopausal women is classified as normal, osteopenia, or osteoporosis according to criteria established by the World Health Organization. Standardized methodologies are being developed to establish cost-effective intervention thresholds for pharmacological therapy based on T-score combined with clinical risk factors for fracture.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Michael Lewiecki, João Lindolfo C Borges. 2006. Bone density testing in clinical practice.. https://doi.org/10.1590/s0004-27302006000400004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗