PubMed Health⌕ Search

PubMed · 17132442

Attenuated total internal reflection infrared microspectroscopic imaging using a large-radius germanium internal reflection element and a linear array detector.

Abstract

The number of techniques and instruments available for Fourier transform infrared (FT-IR) microspectroscopic imaging has grown significantly over the past few years. Attenuated total internal reflectance (ATR) FT-IR microspectroscopy reduces sample preparation time and has simplified the analysis of many difficult samples. FT-IR imaging has become a powerful analytical tool using either a focal plane array or a linear array detector, especially when coupled with a chemometric analysis package. The field of view of the ATR-IR microspectroscopic imaging area can be greatly increased from 300 x 300 microm to 2500 x 2500 microm using a larger internal reflection element of 12.5 mm radius instead of the typical 1.5 mm radius. This gives an area increase of 70x before aberrant effects become too great. Parameters evaluated include the change in penetration depth as a function of beam displacement, measurements of the active area, magnification factor, and change in spatial resolution over the imaging area. Drawbacks such as large file size will also be discussed. This technique has been successfully applied to the FT-IR imaging of polydimethylsiloxane foam cross-sections, latent human fingerprints, and a model inorganic mixture, which demonstrates the usefulness of the method for pharmaceuticals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brian M Patterson, George J Havrilla. 2006. Attenuated total internal reflection infrared microspectroscopic imaging using a large-radius germanium internal reflection element and a linear array detector.. https://doi.org/10.1366/000370206778998941

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Computation of likelihood ratios in fingerprint identification for configurations of any number of minutiae.

Recent court challenges have highlighted the need for statistical research on fingerprint identification. This paper proposes a model for computing likelihood ratios (LRs) to assess the evidential value of comparisons with any number of minutiae. The model considers minutiae type, direction and relative spatial relationships. It expands on previous work on three minutiae by adopting a spatial modeling using radial triangulation and a probabilistic distortion model for assessing the numerator of the LR. The model has been tested on a sample of 686 ulnar loops and 204 arches. Features vectors used for statistical analysis have been obtained following a preprocessing step based on Gabor filtering and image processing to extract minutiae data. The metric used to assess similarity between two feature vectors is based on an Euclidean distance measure. Tippett plots and rates of misleading evidence have been used as performance indicators of the model. The model has shown encouraging behavior with low rates of misleading evidence and a LR power of the model increasing significantly with the number of minutiae. The LRs that it provides are highly indicative of identity of source on a significant proportion of cases, even when considering configurations with few minutiae. In contrast with previous research, the model, in addition to minutia type and direction, incorporates spatial relationships of minutiae without introducing probabilistic independence assumptions. The model also accounts for finger distortion.

Dermatoglyphics↗

Infrared spectroscopic imaging for noninvasive detection of latent fingerprints.

The capability of Fourier transform infrared (FTIR) spectroscopic imaging to provide detailed images of unprocessed latent fingerprints while also preserving important trace evidence is demonstrated. Unprocessed fingerprints were developed on various porous and nonporous substrates. Data-processing methods used to extract the latent fingerprint ridge pattern from the background material included basic infrared spectroscopic band intensities, addition and subtraction of band intensity measurements, principal components analysis (PCA) and calculation of second derivative band intensities, as well as combinations of these various techniques. Additionally, trace evidence within the fingerprints was recovered and identified.

Dermatoglyphics↗

Correlation between IQ and dermatoglyphic indices of Down syndrome patients.

The fingerprint patterns, simian crease, and total ridge count of 41 mild and 61 severe mentally handicapped patients with Down syndrome (DS) were compared with a control group of 200 mentally normal individuals. Patients and controls were unrelated Iranian Muslims. Significant differences were observed within DS patients with different levels of mental retardation.

Dermatoglyphics↗