PubMed HealthSearch

PubMed · 1759599

Cardiac frequency, phase and errors in one-dimensional sensorimotor tracking.

Abstract

One dimensional manual tracking was investigated in relation to actual heart rate and phase of cardiac cycle. Higher heart rate was combined with increased tracking error incidence and decreased successful tracking time (light spot inside target). Error incidence was time-locked with respect to the phase of cardiac cycle.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Indra, Z Bohdanecký, T Radil. 1991. Cardiac frequency, phase and errors in one-dimensional sensorimotor tracking.. https://pubmed.ncbi.nlm.nih.gov/1759599/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Combined historical and electrocardiographic timing of acute anterior and inferior myocardial infarcts for prediction of reperfusion achievable size limitation.

The historical time of acute symptom onset is not always an accurate indication of the timing of onset of an acute myocardial infarction (AMI). Consideration of electrocardiographic (ECG) timing parameters could supplement historical timing alone as a clinical guide for decisions regarding the use of reperfusion therapy. Three hundred ninety-five patients from 4 trials of thrombolytic therapy conducted in the northwestern United States and western Canada are included in the present study. A total of 316 patients received either streptokinase or tissue plasminogen activator, and 79 received no reperfusion therapy. Historical time of symptom onset was acquired by emergency or cardiology department personnel and recorded on patient report forms. An ECG method for estimating the timing of the AMI, the Anderson-Wilkins (AW) acuteness score, was calculated from the initial standard 12-lead recording by investigators blinded to the knowledge of symptom duration or any other study variables. Tomographic thallium-201 imaging 7 weeks after hospital admission was used to measure final AMI size. The ECG timing method achieved a relation with final AMI size similar to that previously reported for historical timing. The AW acuteness score proved most useful for anterior AMI location when there was a > or = 2 hour delay following symptom onset, but was most useful for the inferior AMI location when there was a < 2 hour delay. Despite a longer delay, patients with high AW acuteness scores had 50% lower final anterior AMI size than those with low scores; and despite a shorter delay, those with low ECG acuteness scores had 50% greater final inferior AMI size than those with high scores. The AW acuteness score combined with the historical estimation of symptom duration should provide a more accurate basis for predicting the potential for limitation of final AMI size than either method alone. These results could potentially provide the basis for developing a new method for noninvasive guidance of clinical decisions regarding administration of reperfusion therapy in the initial evaluation of patients with AMI.

Electrocardiography

Pacemaker leads: performance and progress.

Pacing leads remain the "weaker link" of the permanent pacing system. Lead failure has been an issue since the beginning of implantable pacemaker therapy. Modern electronics have brought about considerable progress in pacing technology, but lead design has been slower to evolve and problems persist. IS-1 standardization must be considered a significant advance, but some issues regarding IS-1 standardization persist and have been the cause of some compatibility problems. With respect to lead insulation, silicone has proved to offer total reliability for > 30 years. In the search for better handling characteristics, polyurethane 80A was employed for bipolar leads, but it failed to demonstrate satisfactory insulating properties. New insulation materials, such as ethylene-fluoro-ethylene (ETFE), and coated wire technology look promising, having shown 99.32% survival at 5-year follow-up. Reliability is the main objective in lead design, but leads should provide low battery consumption as well. Low coil resistance, with high electrode impedance in steroid-eluting leads, is the standard at present. Low polarization is a desirable property for 2 main reasons: (1) in conjunction with low-threshold leads, it decreases battery consumption; and (2) it allows capture detection and, therefore, safer pacing at low battery consumption. Lead tip design as well as pacing pulse configuration can influence polarization.

Electrocardiography