Lower extremity angle measurement with accelerometers--error and sensitivity analysis.

Abstract

Closed-loop control techniques for the restoration of locomotion of paraplegic subjects are expected to improve the quality of functional neuromuscular stimulation (FNS). We investigated the use of accelerometers for the assessment of feedback parameters. Previously, the possibility of angle assessment of the lower extremities using accelerometers, but without integration, was demonstrated. The current paper evaluates and assesses this method by an error and sensitivity analysis using healthy subject data. Of three potential error sources, the reference system, the accelerometers, and the model assumptions, the last was found to be the most important. Model calculations based on data obtained by the Elite video motion analysis system showed the rigid-body assumption error to be dominant for high frequencies (greater than 10 Hz), with vibrations in the order of 1 mm resulting in errors of one radial or more. For low frequencies (less than 5 Hz), the imperfect fixation of the accelerometers combined with a nonhinge type knee joint gave an error contribution of +/- 0.03 rad. The walking pattern was assumed to be two-dimensional which was shown to result in an error of +/- 0.04 rad. Accelerations due to rotations of the segments could be neglected. The total error computed for low frequencies (+/- 0.07 rad) was comparable to the experimental difference between the current and the reference system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A T Willemsen, C Frigo, H B Boom. 1991. Lower extremity angle measurement with accelerometers--error and sensitivity analysis.. https://doi.org/10.1109/10.137284

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On the dynamics of a spherical scaffold in rotating bioreactors.

We analyze the dynamics of a spherical scaffold in rotating bioreactors (or clinostats). The idealized clinostat environment consists of a purely rotational flow that is perpendicular to a gravitational field. We confirm through a detailed analytical study that lift effects considerably alter the position of the equilibrium point reached by the scaffolds in the (vertical) direction collinear to the gravitational field. This result holds for small particle and shear Reynolds numbers. Our analysis shows that the inertial lift effect is negligible in the horizontal direction. We show that for all rotations of practical interest, and for the range of particle Reynolds number smaller than unity, the vertical coordinate of the equilibrium point is strongly affected by consideration of lift effects. For light (heavy) particles, inclusion of lift in the formation forces the equilibrium position to be below (above) the horizontal plane that contains the axis of rotation. The equilibrium point for light particles is stable and therefore is observable experimentally. The equilibrium point for heavy particles is unstable. We also estimate the stress level applied to the scaffold and derive an algebraic expression that indicates that the stress level acting on the scaffold decreases with increasing shear Reynolds number.

Acceleration↗

Morphometric relationships of take-off speed in anuran amphibians.

Locomotory speed correlates with muscle mass (determining force and stride rate), limb length (stride rate and distance), and laterally compressed body trunk (force and stride distance). To delineate generalization of the locomotory-morphometric relationships specifically in anuran amphibians, we investigated take-off speed and the three morphological variables from seven species, Rana nigromaculata, R. rugosa, and Bombina orientalis, Eleuthrodectilus fitzingeri, E. diastema, Bufo typhonius, Colostethus flotator and Physalaemus pustulosus. The fastest jumper E. fitzingeri (3.41 m s(-1)) showed 2.49-fold greater speed than the slowest B. typhonius. Take-off speed correlated well with both thigh muscle mass relative to body mass and hindlimb length relative to snout-vent length (HL/SVL), but poorly correlated with the inter-ilial width relative to SVL. The best morphological predictor was HL/SVL (speed=-3.28+3.916 HL/SVL, r=0.968, P<0.0001), suggesting that anuran take-off speed is portrayed well with high gear and acceleration distance characterized by hindlimbs.

Acceleration↗

Predictors of whole-body vibration levels among urban taxi drivers.

To identify a set of important WBV predictors that could be used to develop a statistical instrument for exposure assessment in a large epidemiologic study, a total of 432 WBV measures were taken from a sample of 247 male drivers in Taipei City, Taiwan. In accordance with the ISO 2631-1 (1997) methods, we measured the frequency-weighted vertical acceleration (z-axis) over drivers' seat surface, under conditions representing different types of rides (vacant vs. short vs. long) assigned to random destinations. Mixed effect models were used to analyse the WBV data including repeated measures. For this group of urban taxi drivers regularly exposed to WBV of low intensity (mean = 0.31 ms( - 2), ranging from 0.17 to 0.55 ms( - 2) r.m.s.), our analyses indicated that average driving speed was the primary predictor (p < 0.0001). As average driving speed increased, measured vertical acceleration increased in a quadratic-linear manner (p < 0.0001). Other WBV predictors, after adjusting for the effects of other covariates, included automobile manufacturer (p = 0.02), engine size (p = 0.04), body weight (p = 0.002), age (p = 0.02), use of seat cushion (p = 0.03), and traffic period (p = 0.02). Our study suggests that a similar statistical approach could be employed in future studies to improve the quality and efficiency of WBV exposure assessment in professional drivers.

Acceleration↗