PubMed HealthSearch

PubMed · 1857418

Better speech recognition with cochlear implants.

Abstract

HIGH levels of speech recognition have been achieved with a new sound processing strategy for multielectrode cochlear implants. A cochlear implant system consists of one or more implanted electrodes for direct electrical activation of the auditory nerve, an external speech processor that transforms a microphone input into stimuli for each electrode, and a transcutaneous (rf-link) or percutaneous (direct) connection between the processor and the electrodes. We report here the comparison of the new strategy and a standard clinical processor. The standard compressed analogue (CA) processor presented analogue waveforms simultaneously to all electrodes, whereas the new continuous interleaved sampling (CIS) strategy presented brief pulses to each electrode in a nonoverlapping sequence. Seven experienced implant users, selected for their excellent performance with the CA processor, participated as subjects. The new strategy produced large improvements in the scores of speech reception tests for all subjects. These results have important implications for the treatment of deafness and for minimal representations of speech at the auditory periphery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B S Wilson, C C Finley, D T Lawson, R D Wolford, D K Eddington, W M Rabinowitz. 1991-07-18. Better speech recognition with cochlear implants.. https://doi.org/10.1038/352236a0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Cochlear implantation].

Since the Israeli cochlear implant program was started in June 1989, 74 candidates have been evaluated for implantation. The main causes for hearing loss were meningitis (16 patients), aminoglycoside toxicity (9), congenital (6), viral (e.g. mumps) (6), and middle ear infection. Candidates were rejected mainly due to psychosocial factors (40%) and audiological parameters (30%). 16 postlingual deaf were implanted. In 7 of them (43.7%) the results were excellent, in 4 (25.0%) good, in 3 (18.7%) fair; 1 case is currently in a training program and 1 is a failure. There were 2 major complications: facial nerve palsy which necessitated surgical decompression, and insertion of the electrodes into the hypotympanic air cells, corrected by reoperation.

Cochlear Implants

Performance over time with a nucleus or Ineraid cochlear implant.

This investigation determined whether the audiological performance of cochlear implant users varied with experience. Thirteen Nucleus and 14 Ineraid subjects were evaluated at 1, 9, and 18 mo after cochlear implant connection. Ten Nucleus and five Ineraid subjects were tested at 30 mo. On average, the ability of the subjects to recognize words and phonemes in an audition-only condition improved during the first 9 mo, as did their ability to recognize spondees in noise. The phoneme scores continued to improve during the next 9 mo. Environmental sound recognition improved gradually; significant improvement from the 1 mo scores was not noted until 18 mo. About half of the subjects who demonstrated poor word recognition at 1 mo showed significantly improved percent word correct scores by 18 mo. The Nucleus and Ineraid subjects did not differ in their patterns of change over time. An information transmission analysis performed on the subjects' consonant confusion matrices showed relatively little change for the nasality and place features during the first 18 mo, and relatively large change for the voice, duration, and frication features. Most improvement in the feature scores occurred during the first 9 mo.

Cochlear Implants