Better speech recognition with cochlear implants.

HIGH levels of speech recognition have been achieved with a new sound processing strategy for multielectrode cochlear implants. A cochlear implant system consists of one or more implanted electrodes for direct electrical activation of the auditory nerve, an external speech processor that transforms a microphone input into stimuli for each electrode, and a transcutaneous (rf-link) or percutaneous (direct) connection between the processor and the electrodes. We report here the comparison of the new strategy and a standard clinical processor. The standard compressed analogue (CA) processor presented analogue waveforms simultaneously to all electrodes, whereas the new continuous interleaved sampling (CIS) strategy presented brief pulses to each electrode in a nonoverlapping sequence. Seven experienced implant users, selected for their excellent performance with the CA processor, participated as subjects. The new strategy produced large improvements in the scores of speech reception tests for all subjects. These results have important implications for the treatment of deafness and for minimal representations of speech at the auditory periphery.

Cochlear Implants

Coding strategies for multichannel cochlear prostheses.

Comparisons of analog and pulsatile coding strategies for multichannel cochlear prostheses are reviewed. The results are related to design considerations for pediatric implants, including efficacy, safety, ease of fitting, and access to future improvements.

Adult

Comparative studies of speech processing strategies for cochlear implants.

A wide variety of speech processing strategies for multichannel auditory prostheses were compared in studies of two patients implanted with the UCSF electrode array. Each strategy was evaluated using tests of vowel and consonant confusions, with and without lipreading. Included among the strategies were the compressed analog processor of the present UCSF/Storz prosthesis and a group of interleaved pulses processors in which the amplitudes of nonsimultaneous pulses code the spectral variations of speech. For these patients, each with indications of poor nerve survival, test scores were significantly higher with the interleaved pulses processors. We believe this superior performance was a result of 1. the substantial release from channel interactions provided by nonsimultaneous stimuli and 2. a fast enough rotation among the channels to support adequate temporal and spectral resolution of perceived speech sounds.

Cochlear Implants

Spinal cord seizures elicited by high pressures of helium.

Rats with complete spinal transections were compressed in helium-oxygen to 120 bars. Tremors and increased EMG activity in limbs rostral as well as caudal to the lesions were observed beginning at 30 bars. Spinal seizures occurred at 95 bars, similar to cortical seizure thresholds of intact rats. Denervated limbs remained flaccid throughout the dives. No rostro-caudal progression of symptoms was evident in normal animals, but fluctuation of symptoms with increasing pressure was frequently observed. These findings are consistent with the hypothesis that the effects of pressure on aggregates of neurons exceed those on isolated components.