Abstract

We have developed a method to calculate flow noninvasively in blood vessels using color Motion-mode (M-mode) and computer postprocessing. The velocity of each point in the cross-sectional area of the vessel was found from the color M-mode recording by correcting for angle both distances and velocities and by assuming a symmetrical circular velocity field. Volume flow was then found by integrating the velocity field at 5-ms intervals through the cardiac cycle. In a cardiovascular hydromechanical model, a correlation of 0.99 and p value of less than 0.001 were found between estimated and measured flow in the model (n = 8). In 20 healthy individuals, we made 31 investigations in the common carotid (CCA), internal carotid (ICA), and external carotid (ECA) artery, comparing flow in the CCA with the added flow in the ICA and ECA. The values (CCA versus ICA + ECA) correlated with r = 0.91 and p less than 0.01. Repeated investigations (n = 8) in one individual gave flow estimates of 495 +/- 50 ml/min in the CCA, 304 +/- 45 ml/min in the ICA, and 165 +/- 37 ml/min in the ECA (means +/- SD). This article shows that this system can make accurate estimation of blood flow to the brain noninvasively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Juul, S A Slørdahl, H Torp, B A Angelsen, A O Brubakk. 1991. Flow estimation using ultrasound imaging (color M-mode) and computer postprocessing.. https://doi.org/10.1038/jcbfm.1991.149

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of mitral leaflet motion by echocardiography and jet direction by Doppler color flow mapping to determine the mechanisms of mitral regurgitation.

OBJECTIVES: This study was designed to assess the accuracy of two-dimensional and Doppler echocardiography in determining the mechanism of mitral regurgitation, as compared with direct inspection of the valve at operation. BACKGROUND: Valve repair for mitral regurgitation offers substantial advantages over valve replacement, but it is technically more demanding and requires understanding of the mechanism of dysfunction. METHODS: We studied 286 patients undergoing mitral valve repair. Intraoperative two-dimensional echocardiography was used to classify mitral leaflet motion as excessive, normal or restricted. Doppler color flow mapping was used to evaluate the direction and origin of the mitral regurgitant jet. Two-dimensional and Doppler echocardiography were compared with intraoperative surgical determination of the mechanism of dysfunction, which also classified leaflet motion as excessive, normal or restricted. RESULTS: Two-dimensional and Doppler echocardiography accurately diagnosed the mechanism of mitral regurgitation in 123 (93%) of 132 patients with posterior leaflet prolapse or flail, 30 (94%) of 32 patients with anterior leaflet prolapse or flail, 11 (44%) of 25 patients with bileaflet prolapse or flail, 6 (75%) of 8 patients with papillary muscle elongation or rupture, 31 (91%) of 34 patients with restricted leaflet motion or rheumatic thickening, 21 (72%) of 29 patients with ventricular-annular dilation and 8 (62%) of 13 patients with a leaflet perforation or cleft. Of 13 patients with two mechanisms of dysfunction by surgical inspection, two-dimensional and Doppler echocardiography correctly diagnosed one of the two mechanisms in 12 patients (92%), and both mechanisms in 5 patients (38%). Overall, echocardiographic determination of leaflet motion and Doppler determination of jet direction accurately diagnosed the mechanism of dysfunction in 242 (85%) of 286 patients. CONCLUSIONS: Echocardiography before mitral valvuloplasty provides a dynamic appraisal of the mechanism of dysfunction, enabling the surgeon to systematically understand the dysfunction and successfully apply the correct procedures to eliminate mitral regurgitation without valve replacement.

Blood Flow Velocity

[Transcranial Doppler sonographic study of the effect of electroconvulsive therapy on the circulation in the median cerebral artery].

The authors monitored the circulation of middle cerebral artery in subdominant hemisphere using the transcranial Doppler sonographic method during electroconvulsive treatment. They intravenously administered the patient 500 mg propanididum to put him/her to sleep and 150 mg of suxamethonium for muscle relaxation. The phasis of narcosis and awakening were continuously recorded under the treatment. After the administration of propanididum a sudden brief rise in flow velocity was measured with transient bradycardia followed by tachycardia. After the muscle relaxation the peak flow velocity diminished long lasting and the mean flow velocity fell from 60 cm per second to 30 cm per second average. At the beginning of the electroconvulsive treatment the velocity suddenly rose. The flow velocity increased significantly during the clonic phase of convulsive jerks with the pulsatility indices falling rapidly. Very low pulsatility indices lasted for long period of time during and following clonic convulsions.

Blood Flow Velocity

Transesophageal echocardiography to assess mitral valve function and flow during cardiopulmonary resuscitation.

This study further defines the mechanism of blood flow during closed-chest compression using transesophageal Doppler echocardiography. Although the echocardiographic demonstration of mitral valve closure during closed-chest compression has been used as evidence of direct cardiac compression, mitral valve closure has also been documented to occur during resuscitation by selectively increasing intrathoracic pressure. Transesophageal Doppler echocardiography was used to assess mitral valve position and flow in 17 adult patients undergoing cardiopulmonary resuscitation with a mechanical piston compression device. Left and right ventricular fractional shortening, mitral valve position with chest compression, timing and magnitude of transmitral flow, and anteroposterior chest diameter were recorded. In 12 patients (group I), the mitral valve closed during the down-stroke of chest compression; in the remaining 5 (group II), it opened further. Peak transmitral flow occurred during the release phase and was significantly higher (p < 0.05) in group I (39.5 +/- 9.3 cm/s) than the peak flow in group II (21.3 +/- 5.9 cm/s), which occurred during the downstroke of chest compression. Left ventricular fractional shortening inversely correlated (r = -0.68; p = 0.02) with the anteroposterior chest diameter, but did not correlate with peak transmitral flow (r = 0.34; p = not significant). It is concluded that the mitral valve closes during the downstroke of chest compression in most adult patients during resuscitation. The absence of a relation between mitral valve flow and left ventricular fractional shortening supports the hypothesis that other factors such as nonuniform increases in intrathoracic pressure cause the mitral valve to open or close during chest compression.

Blood Flow Velocity