The two power limits conditioning step frequency in human running.

Abstract

1. At high running speeds, the step frequency becomes lower than the apparent natural frequency of the body's bouncing system. This is due to a relative increase of the vertical component of the muscular push and requires a greater power to maintain the motion of the centre of gravity, Wext. However, the reduction of the step frequency leads to a decrease of the power to accelerate the limbs relatively to the centre of gravity, Wint, and, possibly, of the total power Wtot = Wext + Wint. 2. In this study we measured Wext using a force platform, Wint by motion picture analysis, and calculated Wtot during human running at six given speeds (from 5 to 21 km h-1) maintained with different step frequencies dictated by a metronome. The power was calculated by dividing the positive work done at each step by the duration of the step (step-average power) and by the duration of the positive work phase (push-average power). 3. Also in running, as in walking, a change of the step frequency at a given speed has opposite effects on Wext, which decreases with increasing step frequency, and Wint, which increases with frequency; in addition, a step frequency exists at which Wtot reaches a minimum. However, the frequency for a minimum of Wtot decreases with speed in running, whereas it increases with speed in walking. This is true for both the step-average and the push-average powers. 4. The frequency minimizing the step-average power equals the freely chosen step frequency at about 13 km h-1: it is higher at lower speeds and lower at higher speeds. The frequency minimizing the push-average power approaches the freely chosen step frequency at high speeds (around 22 km h-1 for our subjects). 5. It is concluded that the increase of the vertical push does reduce the step-average power, but that a limit is set by the increase of the push-average power. Between 13 and 22 km h-1 the freely chosen step frequency is intermediate between a frequency minimizing the step-average power, eventually limited by the maximum oxygen intake (aerobic power), and a frequency minimizing the push-average power, set free by the muscle immediately during contraction (anaerobic power). The first need prevails at the lower speed, the second at the higher speed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G A Cavagna, P A Willems, P Franzetti, C Detrembleur. 1991. The two power limits conditioning step frequency in human running.. https://doi.org/10.1113/jphysiol.1991.sp018586

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗