[Methods for ensuring correct tracheal intubation. A review].

Abstract

To confirm correct intubation of the trachea, the literature mentions the following methods: Auscultation of thorax, the sensation of normal ventilation, gastric and thorax movement, condensation of water vapor in the tube lumen, external palpation on the patient's neck of the tube and the cuff, tactile palpation through the patient's mouth of the tube, x-ray of thorax and detection of hemoglobin oxysaturation with pulse oximetry. These methods can be used, but cannot be recommended, because they are not reliable. The following methods are recommended in the literature as reliable: Repeated laryngoscopy when there are direct visualization of the vocal cords, fiberoptic bronchoscopy, suction on the tube with a 60-ml syringe, auscultation of the upper abdomen and lungs and end-tidal carbon dioxide measurement. For the daily routine, control, of the endotracheal tube placement, by auscultation over the epigastrium, then in the right and left axilla, and continuous measurement of carbon dioxide in the expired air are recommended.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K H Andersen. 1991-01-21. [Methods for ensuring correct tracheal intubation. A review].. https://pubmed.ncbi.nlm.nih.gov/1899954/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transmission of lung sounds through light clothing.

BACKGROUND: Doctors are exhorted to always place the stethoscope directly on the skin and never to auscultate through clothing. Nevertheless, casual observation reveals that doctors and even pulmonologists often violate this principle. OBJECTIVES: This study was designed to evaluate the sensitivity of two common stethoscopes when used through clothing. METHODS: Littmann Classic and Littmann Master Cardiology stethoscopes were studied under conditions of light (60-100 g), medium (240 g) and heavy (555 g) force when placed on a lung sound test platform with one or two layers of cloth (T-shirt material and flannel) interposed between the stethoscope and the test surface. The test platform was designed to mimic the acoustic and mechanical properties of the chest wall and was driven by amplified white noise. The recorded amplitude spectra were compared over a range of 150-1,000 Hz. RESULTS: Compared to the sensitivity on a bare test platform surface, either fabric in single or double layers attenuated the sounds by a mean of 5-18 dB under light pressure. This attenuation was nearly abolished by the addition of either medium or heavy force on the stethoscope head. CONCLUSIONS: The deleterious effect of one or two layers of indoor clothing on lung sounds acquired through a stethoscope can be negated by force on the stethoscope head making effective auscultation possible. Nevertheless, auscultation through clothing remains problematic due to the hindrance to inspection and percussion and the risk of acoustic artifacts caused by clothing.

Auscultation↗

A huge obstructive myxoma located in the right heart without causing any symptom.

Cardiac myxoma is unusual and mostly located in left atrium. Although it is a benign tumor of the heart, it may cause life-threatening cardiac problems like valvular obstruction, systemic or pulmonary massive embolism, infection, arrhythmia, malignance. We report a huge cardiac myxoma originated from right atrium. It was moving between right atrium and ventricle without any symptoms.

Auscultation↗