PubMed HealthSearch

PubMed · 203363

Identification of functionally related neural assemblies.

Abstract

Present-day techniques of multiple-electrode together with computer-aided separation of impulses arising from different neurons permit the simultaneous recording of nerve-impulse timings in sets of neurons exceeding 20 in number. This in turn makes it feasible to search for functional groups of neurons, defined as subsets that tend to fire in near simultaneity significantly more often than would independent neurons at corresponding mean rates. A statistical technique is described that permits the detection and identification of such functional groups. The method is accretional, based on identification of associated neurons through interative application of a significance test on multiple coincidences of neuronal firings within an observational window. Examples of the operation of the method and indications as to its sensitivity are furnished through computer simulations of neural networks. The entire algorithm may be used as a screening technique to select smaller groups of neurons for cross-correlational and related finer-grained temporal analyses, or it may be used in its own right to detect and characterize functional groups that are not distinguishable by other statistical procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G L Gerstein, D H Perkel, K N Subramanian. 1978-01-20. Identification of functionally related neural assemblies.. https://doi.org/10.1016/0006-8993(78)90237-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The function relating the subjective magnitude of brain stimulation reward to stimulation strength varies with site of stimulation.

A two-lever choice paradigm with concurrent variable interval schedules of reward was used to measure the growth in the subjective magnitude of reward as a function of current, by finding the adjustment in the stimulating current required to offset a given difference in the rates at which two rewards were received. Increasing current by a factor of 2 increased subjective reward magnitude by a factor ranging from as little as 3 to as much as 4,000. This range was about as great between electrodes within one rat as between electrodes and rats. In the light of earlier findings regarding the equivalent effects of increments is current and pulse frequency, these large differences cannot readily be explained by differing fiber densities at the site of stimulation. It is suggested that the medial forebrain bundle terminates in more than one spatio-temporal integration mechanism. The magnitude of the spatio-temporally integrated effect of a barrage of action potentials in the reward-relevant axons depends on which subset of reward-relevant axons is excited by the stimulation.

Action Potentials

Long-term adaptation of crayfish neurons depends on the frequency and number of impulses.

Increasing the impulse activity of crustacean neurons for a few days causes long-lasting changes in transmitter release, which are termed 'long-term adaptation' (LTA) in previous studies. Both the amount of transmitter released at the beginning of a stimulus train, and synaptic fatigue during repetitive stimulation, are reduced. The present study examines the dependence of these synaptic changes on the frequency and number of impulses used to elicit LTA. Fatigue resistance develops consistently when crayfish phasic motor neurons are stimulated for 3 days with as few as 9,000 impulses per day, and occurs in response either to low frequency stimulation (0.2 or 0.5 Hz), or to stimulation in short bursts at a moderate average frequency (2.5 Hz). In contrast, the reduction in initial transmitter release does not appear consistently when the frequency and number of impulses are both low (9,000 impulses per day delivered at 0.2 Hz), but does occur at the moderate stimulus frequency (2.5 Hz) and when a larger number of impulses (18,000) are delivered at a low frequency (0.5 Hz). The data suggest that the two changes in synaptic transmission that comprise LTA have different stimulus requirements.

Action Potentials

Concentrations of carbachol stimulating phosphoinositide hydrolysis cause a sustained decrease in membrane potential and firing rate: role of inositol and inositol polyphosphate second messengers.

We have investigated the relationship between muscarinic agonist-stimulated phosphoinositide (PI) hydrolysis and electrophysiological responses in rat hippocampal slice preparations. In a previous extracellular study, we found that muscarinic agonists at concentrations that stimulate PI hydrolysis result in a biphasic firing response; an initial increase in firing followed by loss of firing at higher concentrations. To test the hypothesis that variability in obtaining consistent loss of firing is related to depletion of intracellular inositol, we investigated the effects of adding exogenous inositol to the buffer. We now report that concentrations of inositol similar to those in cerebral spinal fluid (30-100 microM) augment carbamylcholine (carbachol, CCh) mediated loss of firing and [3H]inositol-1,3,4,5-tetrakisphosphate ([3H]Ins(1,3,4,5)P4) formation. Inhibition of firing produced by 30 microM CCh in the presence of inositol was associated with a sustained depolarization of 20-25 mV, an increased slope resistance in the depolarized range (-60 to -40 mV), and a parallel shift in the hyperpolarized (-100 to -70 mV) range of the voltage-current curve and increased frequency of spontaneous IPSPs. Under voltage-clamp, measurements of the M-current (IM) showed sustained inactivation by CCh with reversal after washout of CCh. Manual depolarization of cells by current injection to the same level of depolarization as attained with CCh did not usually lead to the same loss of firing. These findings suggest that IM, and possibly other voltage-independent currents or ion pumps, may cause loss of firing only in part through a depolarization blockade of firing and not through desensitization. Furthermore, CCh treatment without inositol did not depolarize neurons as much as CCh with inositol, and usually did not cause a delayed loss of firing. Brain slice preparations may thus require physiological concentrations of inositol to show consistent or maximum phosphoinositide-mediated electrophysiological responses.

Action Potentials