PubMed Health⌕ Search

PubMed · 2034453

Inter- and intra-image variability in computer-assisted optic nerve head assessment.

Abstract

A computer-assisted system for optic nerve head analysis was used to measure one eye from each of 15 subjects. These comprised three groups of five, being glaucomatous, ocular hypertensive, and normal subjects. Each eye was imaged with the system 10 times. The 150 images produced were analysed in a randomized masked fashion to test the inter-image variability of the measurements. Linear pallor: disc ratios had mean coefficients of variation of 6.6% (normal), 4.8% (ocular hypertensive) and 2.6% (glaucomatous). This trend of reducing coefficient of variation from normal to ocular hypertensive to glaucomatous was reflected in other parameters also. Intra-image variability was assessed by analysing one image from each subject 10 times, in a randomized masked fashion. The mean coefficients of variation of the linear pallor: disc ratios were 6.3% (normal), 3.6% (ocular hypertensive) and 3.2% (glaucomatous). Fisher's F-test showed that no parameters had significantly lower intra-image rather than inter-image variance (at the 5% level). Variability is apparently due to operator variations rather than the image variations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Cox, I C Wood. 1991. Inter- and intra-image variability in computer-assisted optic nerve head assessment.. https://pubmed.ncbi.nlm.nih.gov/2034453/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗