Analyses with the KODAK-Ektachem. Accuracy control using reference method values and the influence of protein concentration. Part I. Electrolytes.

Abstract

The reliability of electrolyte determinations with the Ektachem 700 was evaluated by various means including the use of reference method values. The influence of protein concentration, which may alter the viscosity and hence the speed of diffusion, was systematically investigated by using samples of varying protein concentration obtained by ultracentrifugation. Calcium. The mean bias between Ektachem results and reference method values of 9 control sera was -7.3%. In a comparative study with native sera a negative bias was not obtained. The accuracy was independent of the protein concentration. Chloride. The mean bias was -0.1% compared with reference method values. As might be expected, the difference between chloride values with Ektachem--using a "direct" ion-selective electrode--and determinations by coulometry increased with increasing protein concentrations. Magnesium. A negative bias (-5.0%) was obtained in accuracy control with reference method values, and to a smaller extent in a comparative study with native sera. An influence of the protein concentration on the magnesium determination was not observed. Phosphate. Accuracy control by method-dependent assigned values and a comparative study with native sera showed a positive bias. Ektachem results depend on the protein concentration. At 120 g/l protein the bias was +13.6%. Potassium. The mean bias, with respect to reference method values, was -1.2%. At high concentrations of proteins of "normal" composition, Ektachem results agree with measurements by flame atomic emission spectrometry; in paraproteinaemic sera the values are higher. Sodium. The mean inaccuracy was 3.3%, compared with reference method values. The dependence on the amount and composition of the total protein was similar to that found for potassium analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W R Külpmann, P Maibaum, O Sonntag. 1990. Analyses with the KODAK-Ektachem. Accuracy control using reference method values and the influence of protein concentration. Part I. Electrolytes.. https://pubmed.ncbi.nlm.nih.gov/2077095/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of Delta9-tetrahydrocannabinolic acid A in human urine and blood serum by LC-MS/MS.

Delta9-tetrahydrocannabinolic acid A (Delta9-THCA-A) is the precursor of Delta9-tetrahydrocannabinol (Delta9-THC) in hemp plants. During smoking, the non-psychoactive Delta9-THCA-A is converted to Delta9-THC, the main psychoactive component of marihuana and hashish. Although the decarboxylation of Delta9-THCA-A to Delta9-THC was assumed to be complete--which means that no Delta9-THCA-A should be detectable in urine and blood serum of cannabis consumers--we found Delta9-THCA-A in the urine and blood serum samples collected from police controls of drivers suspected for driving under the influence of drugs (DUID). For LC-MS/MS analysis, urine and blood serum samples were prepared by solid-phase extraction. Analysis was performed with a phenylhexyl column using gradient elution with acetonitrile. For detection of Delta9-THCA-A, the mass spectrometer (MS) (SCIEX API 365 triple-quadrupole MS with TurboIonSpray source) was operated in the multiple reaction monitoring (MRM) mode using the following transitions: m/z357 --> 313, m/z357 --> 245 and m/z357 --> 191. Delta9-THCA-A could be detected in the urine and blood serum samples of several cannabis consumers in concentrations of up to 10.8 ng/ml in urine and 14.8 ng/ml in serum. The concentration of Delta9-THCA-A was below the Delta9-THC concentration in most serum samples, resulting in molar ratios of Delta9-THCA-A/Delta9-THC of approximately 5.0-18.6%. Only in one case, where a short elapsed time between the last intake and blood sampling is assumed, the molar ratio was 18.6% in the serum. This indicates differences in elimination kinetics, which need to be investigated in detail.

Blood Chemical Analysis↗