Abstract

Input parameters for the program are the arterial pH, pCO2, and pO2 (measured by a blood gas analyzer), oxygen saturation, carboxy-, met-, and total hemoglobin (measured by a multi-wavelength spectrometer), supplemented by patient age, sex, temperature, inspired oxygen fraction, fraction of fetal hemoglobin, and ambient pressure. Output parameters are the inspired and alveolar oxygen partial pressures, pH,pCO2 and pO2 referring to the actual patient temperature, estimated shunt fraction, half-saturation tension, estimated 2,3-diphosphoglycerate concentration, oxygen content and oxygen capacity, extracellular base excess, and plasma bicarbonate concentration. Three parameters related to the blood oxygen availability are calculated: the oxygen extraction tension, concentration of extractable oxygen, and oxygen compensation factor. Calculations of the 'reverse' type may also be performed so that the effect of therapeutic measures on the oxygen status or the acid-base status can be predicted. The user may choose among several different units of measurement and two different conventions for symbols. The results are presented in a data display screen comprising all quantities together with age, sex, and temperature adjusted reference values. The program generates a 'laboratory diagnosis' of the oxygen status and the acid-base status and three graphs illustrating the oxygen status and the acid-base status of the patient: the oxygen graph, the acid-base chart and the blood gas map. A printed summary in one A4 page including a graphical display can be produced with an Epson or HP Laser compatible printer. The program is primarily intended for routine laboratories with a blood gas analyzer combined with a multi-wavelength spectrometer. Calculating the derived quantities may enhance the usefulness of the analyzers and improve patient care. The program may also be used as a teaching aid in acid-base and respiratory physiology. The program requires an IBM PC, XT, AT or similar compatible computer running under DOS version 2.11 or later. A VGA color monitor is preferred, but the program also supports EGA, CGA, and Hercules monitors. The program will be freely available at the cost of a discette and mailing expenses by courtesy of Radiometer Medical A/S, Emdrupvej 72, DK-2400 Copenhagen NV, Denmark (valid through 1991). A simplified algorithm for a programmable pocket calculator avoiding iterative calculations is given as an Appendix.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Siggaard-Andersen, M Siggaard-Andersen. 1990. The oxygen status algorithm: a computer program for calculating and displaying pH and blood gas data.. https://doi.org/10.3109/00365519009087489

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Regulation of the glycophorin C-protein 4.1 membrane-to-skeleton bridge and evaluation of its contribution to erythrocyte membrane stability.

The band 3-ankyrin-spectrin bridge and the glycophorin C-protein 4.1-spectrin/actin bridge constitute the two major tethers between the erythrocyte membrane and its spectrin skeleton. Although a structural requirement for the band 3-ankyrin bridge is well established, the contribution of the glycophorin C-protein 4.1 bridge to red cell function remains to be defined. In order to explore this latter bridge further, we have identified and/or characterized five stimuli that sever the linkage in intact erythrocytes and have examined the impact of this rupture on membrane mechanical properties. We report here that elevation of cytosolic 2,3-bisphosphoglycerate, an increase in intracellular Ca(2+), removal of cell O(2), a decrease in intracellular pH, and activation of erythrocyte protein kinase C all promote dissociation of protein 4.1 from glycophorin C, leading to reduced retention of glycophorin C in detergent-extracted spectrin/actin skeletons. Significantly, where mechanical studies could be performed, we also observe that rupture of the membrane-to-skeleton bridge has little or no impact on the mechanical properties of the cell, as assayed by ektacytometry and nickel mesh filtration. We, therefore, suggest that, although regulation of the glycophorin C-protein 4.1-spectrin/actin bridge likely occurs physiologically, the role of the tether and the associated regulatory changes remain to be established.

2,3-Diphosphoglycerate↗

Reaction rates of oxygen with hemoglobin measured by non-equilibrium facilitated oxygen diffusion through hemoglobin solutions.

The purpose of this study was to verify the concept of non-equilibrium facilitated oxygen diffusion. This work succeeds our previous study, where facilitated oxygen diffusion by hemoglobin was measured at conditions of chemical equilibrium, and which yielded diffusion coefficients of hemoglobin and of oxygen. In the present work chemical non-equilibrium was induced using very thin diffusion layers. As a result, facilitation was decreased as predicted by theory. Thus, this work presents the first experimental demonstration of non-equilibrium facilitated oxygen diffusion. In addition, association and dissociation rate parameters of the reaction between oxygen and bovine and human hemoglobin were calculated and the effect of the homotropic and heterotropic interactions on each rate parameter was demonstrated. The results indicate that the homotropic interaction--which leads to increasing oxygen affinity with increasing oxygenation--is predominantly due to an increase in the association rate. The heterotropic interaction--which leads to decreasing oxygen affinity by anionic ligands--appears to be effected in two ways. Cl- increases the dissociation rate. In contrast, 2,3-diphosphoglycerate decreases the association rate.

2,3-Diphosphoglycerate↗

Expression, purification, and characterization of human hemoglobins Gower-1 (zeta(2)epsilon(2)), Gower-2 (alpha(2)epsilon(2)), and Portland-2 (zeta(2)beta(2)) assembled in complex transgenic-knockout mice.

Embryonic zeta- and epsilon-globin subunits assemble with each other and with adult alpha- and beta-globin subunits into hemoglobin heterotetramers in both primitive and definitive erythrocytes. The properties of these hemoglobins-Hbs Gower-1 (zeta(2)epsilon(2)), Gower-2 (alpha(2)epsilon(2)), and Portland-2 (zeta(2)beta(2))-have been incompletely described as they are difficult to obtain in quantity from either primary human tissue or conventional expression systems. The generation of complex transgenic-knockout mice that express these hemoglobins at levels between 24% and 70% is described, as are efficient methods for their purification from mouse hemolysates. Key physiological characteristics-including P(50), Hill coefficient, Bohr effect, and affinity for 2,3-BPG-were established for each of the 3 human hemoglobins. The stability of each hemoglobin in the face of mechanical, thermal, and chemical stresses was also determined. Analyses indicate that the zeta-for-alpha exchange distinguishing Hb Portland-2 and Hb A alters hemoglobin O(2)-transport capacity by increasing its P(50) and decreasing its Bohr effect. By comparison, the epsilon-for-beta exchange distinguishing Hb Gower-2 and Hb A has little impact on these same functional parameters. Hb Gower-1, assembled entirely from embryonic subunits, displays an elevated P(50) level, a reduced Bohr effect, and increased 2,3-BPG binding compared to Hb A. The data support the hypothesis that Hb Gower-2, assembled from reactivated epsilon globin in individuals with defined hemoglobinopathies and thalassemias, would serve as a physiologically acceptable substitute for deficient or dysfunctional Hb A. In addition, the unexpected properties of Hb Gower-1 call into question a common hypothesis for its primary role in embryonic development.

2,3-Diphosphoglycerate↗