Interpretation module for screening normal ECG.

Abstract

This work concerns the development of a module for automatic recognition of normal ECGs, i.e. those whose waves morphology do not suggest physiopathological or structural heart alterations. Such a unit constitutes the central part of an administrative system under development which will aid in the management of ECG testing in the primary care delivery level in Chile. This system greatly contributes to the optimal allocation of resources in order to increase the test delivery coverage and to reduce the social and private costs involved. A main feature of the system is that it operates through the screening of normal ECG. This process is performed in a computerized unit whose core is the interpretation module. The design of such a module uses concepts and methods previously developed for the general problem of medical diagnosis, based on fuzzy set theory. The interpretation module parameters were adjusted considering hypothetical and real data covering a wide variety of normal and pathological cases. Then its performance was tested using more than one hundred patients' records chosen at random. Results of this test are given and a discussion, including a comparison with similar commercial equipment, is provided.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Holzmann, U Hasseldieck, E Rosselot, P Estévez, A Andrade, G Acuña. 1990. Interpretation module for screening normal ECG.. https://pubmed.ncbi.nlm.nih.gov/2146480/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Improvement of automated electrocardiographic diagnosis by combination of computer interpretations of the electrocardiogram and vectorcardiogram.

In the international project "Common Standards for Quantitative Electrocardiography" (CSE), diagnostic results of different computer programs for the interpretation of the electrocardiogram (ECG) and of the vectorcardiogram (VCG) were combined, and it was shown that the "combined program" performs better than each program separately. Because the program MEANS (Modular ECG Analysis System) comprises 2 different classification programs--one for the ECG, the other for the VCG--this allowed investigation of whether the combined interpretations would yield a better diagnostic result than either one separately. This approach requires that a VCG always be recorded in addition to the ECG. To circumvent this complication, the VCG was reconstructed from the simultaneously recorded ECG leads. This reconstructed VCG was then interpreted by the VCG classification program, whereupon the diagnostic interpretations of the ECG and the reconstructed VCG were combined. For the validation, the CSE database of documented ECGs and VCGs (n = 1,220) was used. The combination of the ECG and VCG interpretations yielded a better diagnostic result than each interpretation program separately (total accuracy 74.2% (ECG + VCG) vs 69.8% (ECG) and 70.2% (VCG), p less than 0.001 in both cases). The results for the reconstructed VCG (total accuracy 70.5%) are comparable to those for the ECG and the VCG (p greater than 0.10 in both cases). The performance of the combined interpretations of ECG and reconstructed VCG (total accuracy 73.6%) is approximately the same as that of the combined ECG and VCG (p greater than 0.10). Thus, the performance of an ECG computer program can be improved by incorporating both ECG and VCG classificatory knowledge, using only the ECG itself.

Diagnosis, Computer-Assisted

[Potential usefulness of computer-aided diagnosis (CAD) in a mass survey for lung cancer using photo-fluorographic films].

We investigated the potential usefulness of computer-aided diagnosis (CAD) in a mass survey for lung cancer. When the sensitivity of the computer output was adjusted nearly equal to that of the mass survey in our database which contained 198 photofluorographic films, some shadows detected by the computer output were different from those detected by human observers. Therefore, the best estimated sensitivity of an observer using the computer output was equal to or greater than the sensitivity of double reading. It is expected that CAD may have a role in a mass survey for lung cancer using photofluorographic films.

Diagnosis, Computer-Assisted