A multiple-frequency hydrophone calibration technique.

Abstract

A method is described for comparing the sensitivity of two hydrophones over the frequency range 1-15 MHz. This technique forms the basis for the dissemination of national ultrasonic standards in the U.K. over this frequency range. A reference hydrophone is placed in an ultrasonic field and then the device being calibrated is substituted and the two output voltages are compared. This substitution method utilizes a broadband ultrasonic field produced by nonlinear propagation. Thus it is possible to cover the whole frequency range with a single measurement on each hydrophone. The overall uncertainty in the intercomparison of two hydrophones increases from +/- 4.2% at 1 MHz to +/- 8.2% at 15 MHz (95% confidence level). The method has been compared with discrete-frequency substitution, time-delay spectrometry, and absolute calibrations using the National Physical Laboratory (NPL) Primary Standard Laser Interferometer. Various designs and sizes of hydrophones were compared, and agreement was within the combined random uncertainties for all the comparisons.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Smith, D R Bacon. 1990. A multiple-frequency hydrophone calibration technique.. https://doi.org/10.1121/1.399191

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acoustic probe-based ELISA.

The effects of acoustic microstreaming during incubation steps of a prototypical three-step ELISA were studied. Acoustic microstreaming, an orderly mixing of microwell contents induced by linear oscillation of immersible acoustic probes, was shown to be particularly effective when coupled with locating the solid phase on the surface of the probes. Optical densities achieved for acoustic probe-based assays were equivalent to those for uninsonated microwell-based assays with only 20% of the microwell solid phase surface area. Low-level antibody detection was significantly improved and antibody incubation times significantly shortened without loss of signal. Acoustic probe-based assays can enhance assay and laboratory efficiency through testing for multiple analytes in a single sample or increasing available binding surface area (by using probe and well surfaces simultaneously), and by eliminating quenching. Acoustic probe ELISA methodology has significant implications for cost-effective automation.

Acoustics