PubMed HealthSearch

PubMed · 2231106

Visual artifacts in chromatically subsampled images.

Abstract

Colors sampled in an array of pixels were converted into various luminance-chrominance representations, and the chrominance values were spatially subsampled to achieve a compression of the data. For viewing, the chrominance values were reinterpolated and then transformed back to RGB. For each of a range of image types and color spaces, we varied the chromatic sample spacing to determine how much compression would be possible before perceptual artifacts appeared, as determined by a panel of individual viewers. The spacing at which an image was mistaken half the time for a remembered original depended on image content and also on the color representation. Some color spaces, such as hue-lightness-saturation, a polar-coordinate color space, are inherently ill suited for chrominance averaging and produce noticeable artifacts on almost any image. Likewise, some images cannot be subsampled satisfactorily, regardless of the color space used. In general, however, images with 16-fold reduction in the amount of chrominance information (that is, a factor of 4 in each spatial direction) are still satisfactory in appearance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Sigel, R A Abruzzi, J Munson. 1990. Visual artifacts in chromatically subsampled images.. https://doi.org/10.1364/josaa.7.001969

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Readability and sensitivity of a new faecal occult blood test in a hospital ward environment. Comparison with an established test.

OBJECTIVE: To compare the readability and sensitivity of a new guaiac faecal occult blood test, HemoccultSENSA, with those of a standard guaiac-based test, Hemoccult, in a normal working environment. DESIGN: The two tests were performed in parallel on routine clinical and contrived faecal specimens; those developing the tests were blinded as to the test type. SETTING: All tests were carried out in the hospital ward environment under normal conditions by nurses working in the ward. SAMPLES: Fifty faecal samples from healthy volunteer subjects (low concentrations of haemoglobin were added to 40 of these samples) and 145 faecal samples from 65 inpatients likely to have gastrointestinal bleeding. MAIN OUTCOME MEASURES: Test positivity rate, and graded measures of colour intensity, colour stability and colour pattern. RESULTS: With patients' samples, the new test gave a greater number of positive results than the standard test (73.1% v. 65.5%; 95% confidence interval of the difference, 3.3%-11.9%). With contrived samples, the blue colour produced during development was more intense (P less than 0.0003), more stable (P less than 0.0025) and covered a larger area (P less than 0.01) with the new test compared with the standard test. CONCLUSIONS: These results demonstrate the better readability and slightly higher sensitivity of the new test. They justify its use in the ward environment or doctor's office. Patients being tested should consume a low peroxidase diet until the specificity of the new test has been fully evaluated.

Color