Segmental vascular resistance in postobstructive pulmonary vasculopathy.

Abstract

Chronic unilateral pulmonary arterial ligation has been touted as a model of arteriopathy resulting in a tremendous increase in anastomotic bronchial flow (Qbr) via collaterals. To investigate its effects on the pulmonary vasculature, we ligated the left main pulmonary artery of seven dogs and 120 days later pump perfused their left lower lobes (LLL) via a cannula in the pulmonary artery at pulmonary arterial flow (Qpa) of 250 ml/min. We measured Qbr (330 ml/min) and compared LLL with control contralateral right lower lobes (RLL) and three LLL from normal dogs. Pressure-flow (P-Q) curves were obtained by varying Qpa. With arterial and venous occlusion we measured total, arterial, venous, and middle segment resistances under baseline conditions, after serotonin and histamine, either with or without Qpa and with antegrade and retrograde Qbr. Light microscopy was done postmortem. The slope of the P-Q curve was 33.4 mmHg.l-1.min in the ligated lobes compared with 15.9 in the controls, attributable by the occlusion technique mainly to a rise in arterial resistance (22.4 mmHg.l-1.min compared with 7.4 in the controls) with a small rise in venous resistance. This was explained by significant arterial medial muscle thickening and some loss of LLL volume. The arterial segment was markedly hypersensitive to serotonin, and the venous segment was mildly hypersensitive to histamine compared with controls. The occlusion data also enabled us to model the point of entry of the bronchial circulation into the pulmonary circuit at the precapillary level and to calculate bronchial vascular resistance. We conclude that postobstructive vasculopathy substantially raises pulmonary vascular resistance, mainly upstream from the site of entry of the bronchial circulation. The role of the latter may be to keep it from rising excessively in the segments it perfuses, i.e., the middle and venous ones.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R P Michel, T S Hakim, D Petsikas. 1990. Segmental vascular resistance in postobstructive pulmonary vasculopathy.. https://doi.org/10.1152/jappl.1990.69.3.1022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of pulsatile tidal volume, pressure amplitude, and gas flow during high-frequency percussive ventilation, with and without partial cuff deflation.

OBJECTIVE: With a high-frequency percussive ventilator and a mechanical lung model, to measure tidal volume (V(T)), pulsatile pressure amplitude (difference between peak and nadir pulsatile pressure [DeltaP];), and mean airway pressure (P (aw)) at various pulsatile frequencies, pulsatile inspiratory-expiratory ratios (I:E(p)), and pressures (measured at the interface between the pulse-generator and the endotracheal tube [P(vent)]). METHODS: With the endotracheal tube inside an artificial trachea, we manipulated the high-frequency percussive ventilation settings and adjuncts, including pulsatile frequency, I:E(p), and P(vent) by manipulating pulsatile flow. We also studied the effects of partially deflating the endotracheal tube cuff. We measured P (aw), pulsatile pressure amplitude at the carina (DeltaP(c)), and pulsatile V(T) at the carina. With the cuff partly deflated, we measured the fraction of inspired oxygen (F(IO(2))) in the gas efflux above and below the cuff. RESULTS: Increasing the pulsatile frequency from 300 cycles/min to 600 cycles/min and changing the I:E(p) from 1:3 to 1:1 significantly reduced V(T) (p < 0.001). P (aw) and DeltaP(c) were unaffected by the change in pulsatile frequency or I:E(p), except when we did not preserve the pulsatile flow. The measured V(T) range was from 19.1 mL (at 600 cycles/min) to 47.3 mL (at 300 cycles/min). Partial cuff deflation did not significantly reduce P (aw) or DeltaP(c), but it did significantly reduce V(T) and F(IO(2)). CONCLUSION: During high-frequency percussive ventilation, the pulsatile frequency is inversely related to V(T). Partial cuff deflation reduces the delivered F(IO(2)).

Air Pressure↗

Comparison of automatic and continuous positive airway pressure in a night-by-night analysis: a randomized, crossover study.

BACKGROUND: Long-term compliance is suboptimal in the treatment of the obstructive sleep apnea syndrome (OSAS). OBJECTIVES: We compared the efficacy of and the adherence to automatic continuous positive airway pressure (APAP) and constant continuous positive airway pressure (CPAP) based on a night-by-night analysis. METHODS: We performed a randomized, single-blind crossover study in 20 patients with moderate-to-severe OSAS. After diagnostic polysomnography and manual titration, patients were treated for 8 weeks with both constant CPAP and APAP in random order. Compliance and leakage were analyzed night by night using the software LOGSoft of the Magellan iPAP device. RESULTS: The reduction in the apnea/hypopnea index (baseline 32.9 +/- 19.1/h, CPAP 4.6 +/- 2.9/h, APAP 5.6 +/- 3.6/h; p < 0.001 compared to baseline) and the Epworth Sleepiness Scale (baseline 10.3 +/- 5.7, CPAP 6.6 +/- 4.8, APAP 4.9 +/- 4.6; p < 0.001 compared to baseline) did not significantly differ between the treatment modes. Leakage time and compliance per night were not statistically different (leakage CPAP 31 +/- 57 min, APAP 25 +/- 49 min; compliance CPAP 383 +/- 116 min, APAP 382 +/- 107 min). There was no correlation between leakage and compliance. Thirteen patients (65%) preferred APAP at the end of the study. CONCLUSIONS: Treatment efficacy and adherence are similar with CPAP and APAP. There is a trend towards lower leakage with APAP therapy. Patients prefer the automatic mode to fixed pressure.

Air Pressure↗