PubMed · 2392030
Incidental magnetization transfer contrast in standard multislice imaging.
Abstract
Radio frequency magnetic fields from 5 to 100 kHz off resonance reduce longitudinal magnetization of water in some tissues without affecting the magnetization of simple solutions (Wolff, S.D.; Balaban, R.S. Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn. Reson. Med. 10:135-144; 1989). We demonstrate that off resonant fields used in day to day multislice imaging have a significant effect. Extra slices reduced brain (gray and white matter) and muscle intensities 10%-20% relative to fat, water, and paramagnetic solutions, a larger effect than produced by slice overlap. Implications for image contrast and quantitation are discussed.