Long-term threshold stability with porous tip electrodes.

Abstract

Experience with 163 unipolar tined porous endocardial electrodes is reported. One patient required repositioning of the electrode because of exit block. There were no other complications in the entire series of patients. All of the patients had low chronic stimulation thresholds. The mean pulse width 24 hours after implantation was 0.0534 +/- 0.0128 ms. Seventy-four patients were restudied six months after implantation. The mean pulse width threshold was then 0.07432 +/- 0.0775 ms. Fifty-four patients were evaluated one year after lead implantation. The mean pulse width threshold was then 0.0611 +/- 0.0230 ms. The pulse generator was reprogrammed to a lower pulse width in all of the patients. This permitted a substantial prolongation of the pulse generator life. The cost effectiveness of the pulse generator was also greatly improved by pacing with reduced pulse widths. In an additional 16 patients, the voltage amplitude was reduced from 5.0 volts to 2.5 volts. This permitted an even greater increase in the pulse generator longevity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Gould, C Patel, W Becker. 1986. Long-term threshold stability with porous tip electrodes.. https://doi.org/10.1111/j.1540-8159.1986.tb06694.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The development of a multichannel electrode array for retinal prostheses.

The development of a multielectrode array is the key issue for retinal prostheses. We developed a 10 x 10 platinum electrode array that consists of an 8-microm polyimide layer sandwiched between 5-microm polymonochloro-para-xylylene (parylene-C) layers. Each electrode was formed as a 30-microm-high bump by Pt/Au double-layer electroplating. We estimated the charge delivery capability (CDC) of the electrode by measuring the CDCs of two-channel electrode arrays. The dimensions of each electrode of the two-channel array were the same as those of each electrode formed on the 10 x 10 array. The results suggest that for cathodic-first (CF) pulses, 80% of electrodes surpassed our development target of 318 microC/cm2, which corresponds to the charge density of pulses of 500 micros duration and 200 microA amplitude for a 200-microm-diameter planar electrode.

Electrodes, Implanted↗

Improved version of the printed circuit board (PCB) modular multi-channel microdrive for extracellular electrophysiological recordings.

The modular multi-channel PCB microdrive was described some years ago, since then several improvements were introduced while using these drives. Utilizing several years of experience with the original PCB microdrive we redesigned it to improve its stability and usability. The application of the printed circuit board technology and the extensive use of flexible fused silica capillaries for fabrication of the microdrive are described in detail. The improved design led to a low cost and light-weight multi-channel microdrive with outstanding modularity for extracellular field, single unit or multiunit tetrode recording up to 64/128 channels.

Electrodes, Implanted↗