PubMed Health⌕ Search

PubMed · 2432578

Clinical experience with an activity sensing pacemaker.

Abstract

During clinical evaluation of the Medtronic Activitrax pacemaker in a worldwide multicenter study, implant and follow-up data were provided by 61 investigators on 222 patients. Pacing indications included two- and three-degree AV block in 149 and atrial arrhythmias in 174 patients; 16 patients received atrial pacing. Average and longest documented follow-up periods were 7.5 and 16 months respectively. Paired treadmill tests, one in Activity mode and one in VVI/AAI mode, were performed by 120 patients. At peak exercise, average heart rate was 95 bpm in VVI/AAI mode and 118 bpm in Activity mode (p less than 0.0001). Average exercise time was 9.4 minutes in VVI/AAI mode and 10.8 minutes in Activity mode (p less than 0.0001). In 54 patients who exclusively had paced rhythm during both treadmill tests, average heart rates and exercise times were 70 ppm and 8.1 minutes in VVI/AAI mode and 111 ppm and 10.3 minutes in Activity mode respectively (p less than 0.0001). 24-hour Holter recordings typically demonstrated pacing at or near basic rate during periods of rest and appropriate increase in pacing rate during daily activities. Patients had significantly fewer problems with physical effort in daily life during a week of Activity mode pacing than during a week of VVI/AAI mode pacing (p less than 0.05) as assessed from the symptom scores recorded by 62 patients in special diaries.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F W Lindemans, I R Rankin, R Murtaugh, P A Chevalier. 1986. Clinical experience with an activity sensing pacemaker.. https://doi.org/10.1111/j.1540-8159.1986.tb06657.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On the exact interval estimation for the difference in paired areas under the ROC curves.

An important measure for comparison of accuracy between two diagnostic procedures is the difference in paired areas under the receiver operating characteristic (ROC) curves. Non-parametric and maximum likelihood methods have been proposed for interval estimation for the difference in paired areas under ROC curves. However, these two methods are asymptotic procedures and their performance in finite sample sizes has not been thoroughly investigated. We propose to use the concept of generalized pivotal quantities (GPQs) to construct an exact confidence interval for the difference in paired areas under ROC curves. A simulation study is conducted to empirically investigate the probability coverage and expected length of the three methods for various combinations of sample sizes, values of the area under the ROC curve and correlations. Simulation results demonstrate that the exact confidence interval based on the concept of GPQs provides not only sufficient probability coverage but also reasonable expected length. Numerical examples using published data sets illustrate the proposed method.

Clinical Trials as Topic↗

An efficient test for the analysis of dichotomized variables when the reliability is known.

A difference in an outcome variable between the treatment groups in a trial does not necessarily mean that there is a difference in the number of patients who experience relevant improvement on that variable. When the relevant improvement corresponds with an outcome or change in outcome that exceeds a certain threshold, the outcome variable can be dichotomized. A responder is a patient whose outcome exceeds the threshold. Comparisons can be made between the number of responders in the two treatment groups using logistic regression, or some other method to evaluate binary outcomes. An important disadvantage of this approach is the loss of power. In general, it is more efficient to test the difference between the mean values. We developed a statistical test that compares response rates for a dichotomized variable. It requires that an estimate of the reliability of the outcome variable is available. Simulations showed that the test was valid and robust over a wide range of distributions and sample sizes. The power was greater than the power of a chi(2) test, which would enable substantial reduction in the sample size.

Clinical Trials as Topic↗

Sample size determination for logistic regression revisited.

There is no consensus on the approach to compute the power and sample size with logistic regression. Some authors use the likelihood ratio test; some use the test on proportions; some suggest various approximations to handle the multivariate case. We advocate the use of the Wald test since the Z-score is routinely used for statistical significance testing of regression coefficients. The null-variance formula became popular from early studies, which contradicts modern software, which utilizes the method of maximum likelihood estimation (MLE), when the variance of the MLE is estimated at the MLE, not at the null. We derive general Wald-based power and sample size formulas for logistic regression and then apply them to binary exposure and confounder to obtain a closed-form expression. These formulas are applied to minimize the total sample size in a case-control study to achieve a given power by optimizing the ratio of controls to cases. Approximately, the optimal number of controls to cases is equal to the square root of the alternative odds ratio. Our sample size and power calculations can be carried out online at www.dartmouth.edu/ approximately eugened.

Clinical Trials as Topic↗