[Dynamic 2-chamber overdrive stimulation with an implantable pacemaker system as a method for terminating slow ventricular tachycardias].

Abstract

A case report is given on a new method for treatment of drug-resistant slow ventricular tachycardias by automatic dynamic overdrive stimulation, using an implantable pacemaker system. In a 60-year-old patient with coronary heart disease and ventricular tachycardia refractory to drug therapy, an antitachycardia Medtronic pacemaker (type SP 0501) was implanted in October 1984 and used successfully in 65 attacks during 13 months. However, when trying to terminate the tachycardia by means of programmed stimulation, acceleration of the ectopic ventricular rate occurred at 8 occasions. The administration of the experimental antiarrhythmic drug diprafenone (Class Ic) resulted in a reduction of the ventricular frequency but not of the rate of attacks. Then the Vitatron Quintech DDD pacemaker was implanted, providing the chance of terminating the now reduced ventricular rate by the dynamic overdrive mode.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Heuer, B Frenking, H Gülker, F Bender. 1986. [Dynamic 2-chamber overdrive stimulation with an implantable pacemaker system as a method for terminating slow ventricular tachycardias].. https://pubmed.ncbi.nlm.nih.gov/2433844/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[CME-ECG 2].

Explore the source record for details and available documents.

Cardiac Complexes, Premature↗

Extrasystoles: side effect of kangaroo care?

OBJECTIVE: To present an unpublished reason for an arrhythmic electrocardiogram (ECG) recording during kangaroo care in a preterm infant. DESIGN: Case report. PATIENT: Preterm infant. MEASUREMENTS AND MAIN RESULTS: A preterm infant exhibited cardiac arrhythmia on the ECG monitor during kangaroo care, leading to interruption of kangarooing. Arrhythmia disappeared after placing the baby back into the incubator. The most likely reasons for arrhythmia were excluded. However, arrhythmia reappeared upon continuation of kangaroo care. ECG monitoring revealed the reason for the monitoring error. CONCLUSIONS: ECG monitoring during kangaroo care should cause error because of superimposed electric activity from the parent. Oxygen saturation represents a more reliable method of monitoring during kangaroo care.

Cardiac Complexes, Premature↗