[Pupillographic perimetry using the "Octopus"].

Abstract

The Octopus 2000 computerized perimeter (Interzeag, Schlieren, Switzerland) is combined with an infrared videopupillograph (Demel, Haan, FRG) which at the same time records the direct pupil light response and controls fixation. Digital processing of the pupil video image is performed at a rate of 25 cps. A transient oscilloscope display of the pupil surface after each light stimulus covers the subsequent 1000 ms, so that either pupillary light reflexes or the lack of a response can immediately be identified. An additional continuous penwriter printout shows light stimuli, pupil responses and the subject's responses. Thus, potential discrepancies between the pupil response and the subject's response are clearly revealed. The examination conditions slightly deviate from the standard ones used with the Octopus. Stimulus size is analogous to the target Goldmann/V, the stimulus duration 100 ms and the adaptive illumination 1 cd/m2. Pupil fatigue considerably exceeds visual fatigue. Therefore standard Octopus perimetric programs are inconvenient for pupilloperimetric purposes. A Sargon-based pupilloperimetric program determines pupillomotor increment thresholds at 12 stimulus locations throughout the visual field (20 degrees nasal, 0 degrees, 20 degrees and 40 degrees temporal/15 degrees above the 0 degrees meridian, 0 degrees meridian and 15 degrees below the 0 degrees meridian) while applying the normal Octopus strategy of threshold calculation. Instead of the patient's subjective responses, the examiner's assessment of pupil responses provides the basis for threshold determination by the Octopus program. The subjects are unaware of the mode of examination. Their rating of "seen" or "not seen" ist displayed together with the pupil responses, thus providing a hard copy as proof of malingering or of appropriate cooperation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Alexandridis, H Krastel. 1989. [Pupillographic perimetry using the "Octopus"].. https://pubmed.ncbi.nlm.nih.gov/2625300/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗