PubMed · 2637875

Information gain at reduced exposure time using a prototype video-enhancement device.

Abstract

An experimental imaging device based on analogue video-enhancement was evaluated by comparing the information yield of three different screen/film radiographic combinations with that from conventional viewing methods. Twenty radiographic images of variable density for each screen/film combination were produced by exposing a test object for between 0.1 and 6.6 s and examined by 10 observers in two trials. Perceptibility curves were generated from the data to measure the information yield of each system. Multiple non-parametric t tests demonstrated no loss of information with the experimental device in the diagnostically useful exposure range (15-60 impulses). In addition, this range was extended, with the faster film/screen combinations, to lower exposures (8-12 impulses), suggesting that the device also has the potential to reduce radiation exposure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D A Miles, M L Van Dis, M G Peterson. 1989. Information gain at reduced exposure time using a prototype video-enhancement device.. https://doi.org/10.1259/dmfr.18.3.2637875

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance comparison of an active matrix flat panel imager, computed radiography system, and a screen-film system at four standard radiation qualities.

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Radiographic Image Enhancement↗