PubMed Health⌕ Search

PubMed · 2649926

Grade I hydronephrosis: pulsed Doppler US evaluation.

Abstract

This study was undertaken to determine whether the presence of blood vessels could mimic the appearance of grade I hydronephrosis on sonograms and thus cause false-positive readings. One hundred consecutive patients with grade I hydronephrosis were examined. Sample volumes were obtained with pulsed Doppler ultrasonography (US) at the site of the greatest separation of the central renal sinus echoes to determine if the separation was fluid accumulating in the collecting system, as in obstruction, or if the separation was actually caused by vessels that mimic hydronephrosis. Vascular structures accounted for the separation of the sinus echoes in 43% of patients. In patients 12 years of age or younger, this frequency rose to 61%. The simple procedure of evaluating the renal sinus echo separation with pulsed Doppler US should decrease the frequency of false-positive diagnoses of hydronephrosis and thus diminish the need for further confirmatory testing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F H Scola, J J Cronan, B Schepps. 1989. Grade I hydronephrosis: pulsed Doppler US evaluation.. https://doi.org/10.1148/radiology.171.2.2649926

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Novel homogenous time-resolved fluorometric RT-PCR assays for quantification of PSA and hK2 mRNAs in blood.

OBJECTIVES: The purpose of this study was to design, validate, and optimize internally standardized real-time quantitative RT-PCR assays and to identify and avoid problems with assay reliability and examine the impact of an exogenous internal standard. DESIGN AND METHODS: The model system consisted of internally standardized quantitative real-time RT-PCR assays specific for PSA and hK2 mRNA based on time-resolved fluorometric detection of lanthanide chelates. RESULTS: Reproducibility was best when large copy numbers (>5000 per milliliter blood) were analyzed. Addition of an exogenous target-mimicking internal standard had no significant effect on the reproducibility of the method, but increased the calculated copy numbers by an average of 2-fold. CONCLUSIONS: We developed an internally standardized, specific and reproducible real-time RT-PCR analysis method for PSA and hK2 mRNA in circulating cells in the bloodstream. Both PSA and hK2 assays are sufficiently sensitive to detect two LNCaP cells per milliliter whole blood.

False Positive Reactions↗