Arterial flow characterization with a photodiode array based imaging system.

Abstract

An x-ray imaging system is described that can be used for obtaining arterial blood flow information. The system consists of a linear photodiode array image detector, simple optical and mechanical components, and a data acquisition microcomputer that connect to a conventional x-ray image intensifier based fluorography system. Flow information is obtained by detecting the movement of a small, locally injected bolus of radio-opaque contrast agent. This is done by determining the bolus mass, integrated over the cross-sectional area, at each of 1024 positions along the length of the artery with a sampling rate of up to 200 samples per s. It is shown in a phantom study that the peak flow velocity can be measured with an accuracy of +/- 5% by detecting the bolus arrival times at each of the 1024 positions. The mean velocity is obtained with similar accuracy using a cross-correlation technique and a modified form of the Stewart-Hamilton principle. In addition, it is shown that the separation and reattachment points resulting from flow separation near a stenosis can be determined from the bolus clearance times. The locations of these points are consistent with theoretical values for the cosine shaped symmetric 89% stenosis used in this study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I A Cunningham, S Yamada, B B Hobbs, A Fenster. Arterial flow characterization with a photodiode array based imaging system.. https://doi.org/10.1118/1.596411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.

Angiography↗