PubMed Health⌕ Search

PubMed · 267432

Leukapheresis: the process.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Tenczynski. 1977. Leukapheresis: the process.. https://pubmed.ncbi.nlm.nih.gov/267432/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prevalence of human T-cell leukemia virus types I and II in Switzerland.

The retroviruses human immunodeficiency virus (HIV)-1/2 and human T-cell leukemia virus (HTLV)-I/II share modes of transmission, suggesting that efforts to monitor the current HIV-1 epidemic in Switzerland should be complemented by assessment of HTLV-I/II prevalence. This study presents an updated evaluation of HTLV-I/II infection among groups within the Swiss population polarized towards either low or increased risk of infection. Archived serum and peripheral blood mononuclear cell (PBMC) samples were examined for evidence of HTLV-I/II infection by enzyme-linked immunosorbant assay (ELISA), type-specific Western blot, type-specific polymerase chain reaction (PCR), DNA sequence analysis, and virus culture. Among blood donations obtained from low-risk Swiss donors, we report a complete lack of HTLV-II infection and the occurrence of HTLV-I infection limited to a prevalence of 0.079 per 100,000 (1/1,266,466). Among high-risk HIV-positive persons and HIV-negative persons at increased risk of HIV-infection, we report a focus of HTLV-I and HTLV-II infection at prevalence rates of 62 per 100,000 (1/1,620) and 309 per 100,000 (5/1,620), respectively. The finding of low HTLV-I/II prevalence among Swiss blood donors and containment of HTLV-I/II infection within known risk-groups does not support initiation of HTLV-I/II screening for Swiss blood, tissue, and organ donations.

Blood Donors↗

Quantitative real-time detection of parvovirus B19 DNA in plasma.

BACKGROUND: As of 2004, the European Pharmacopoeia demands that plasma pools for production of anti-D immunoglobulin should not contain more than 104 IU per mL of parvovirus B19 (B19V) DNA. Hence, before pooling, highly viremic donations have to be identified, and after pooling the level of B19V DNA must be determined. The performance of a new real-time B19V DNA PCR test (Roche, Mannheim, Germany) was studied, using a DNA extractor (NucliSens, bioMerieux, Boxtel, the Netherlands) for isolation of nucleic acid, and using a DNA quantification test (LightCycler apparatus, Roche, Mannheim, Germany) for amplification and detection. STUDY DESIGN AND METHODS: Dilutions of the international B19V DNA standard and reference preparations were tested to determine the precision, linear range, and accuracy of the assay and to calculate the factor for conversion of B19V DNA copies to IUs. The internal control signals, invalid test results, and the effect of cryo-poor plasma were studied as a measure for robustness. Routine performance was assessed by testing 164 manufacturing pools (not screened for B19V) and 1048 test pools of 480 donations each. RESULTS: The copies-to-IU conversion factor was calculated to be 3.34 (95% CI, 3.07-3.63). The assay appears linear between 10(3) and 10(7) IU per mL. Between 10(3) and 10(5) IU per mL, the test can discriminate samples differing a factor two in B19V DNA content. Overall, 0.78 percent of the test results were invalid. Of 127 B19V DNA negative control plasma samples, 7 were contaminated with low levels of B19V DNA. Of 164 nonscreened manufacturing plasma pools, 92 contained B19V DNA (56%); 13 contained more than 10(4) IU per mL. Of 503,040 donations, 29 contained more than 5 x 10(6) IU per mL B19V DNA (1:17,346). CONCLUSION: The B19V DNA quantification test (LightCycler, Roche ) is suitable for quantitative, routine, in-process measurement of B19V DNA levels in plasma pools, using the DNA extractor (NucliSens, bioMerieux) for nucleic acid isolation.

Blood Donors↗