PubMed HealthSearch

PubMed · 2749966

[Initial experience with laser retinal surgery].

Abstract

The authors describe 21 cases with resection of the retinal rupture valve with Nd:YAG laser impulse, performed to reduce the vitreoretinal tractions. Resection of the 'dump' rupture valve has been carried out in 10 cases, in the rest 11 the operation has been performed in the presence of a detachment of the retina. Anatomic success (detachment of the valve from the retina) has been achieved in 16 cases. The technique of the surgery is described, as are indications and contraindications to the operation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V S Akopian, N N Pivovarov, S V Glukhoded, I V Gurova. [Initial experience with laser retinal surgery].. https://pubmed.ncbi.nlm.nih.gov/2749966/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Transjugular intrahepatic portosystemic stent shunt (TIPSS) with use of Rösch-Uchida transjugular liver access set--evaluation by CT and its clinical application].

Appropriateness of the Rösch-Uchida transjugular liver access set designed for TIPSS procedure was confirmed, especially about the catheter angle and effective length of the 20 G puncture needle, by CT analysis on three dimensional vascular anatomy of the liver. Clinically, TIPSS using the set was successfully made for two patients, connecting superior right hepatic vein with right portal vein in one patient and middle hepatic vein with left portal vein in another patient with hypoplastic right portal vein. Prior to TIPSS procedure, verification of vascular anatomy on CT images is the key to success of TIPSS in safe.

Evaluation Studies as Topic

[Testing an ultrasonic scanner for determination of urinary bladder volume].

Bladderscan BVI 2000 is a portable ultrasound scanner, specially constructed for determination of bladder volume. We have tested this scanner for accuracy, systematic errors and the training required to use it. The bladder volumes measured by ultrasound scanning were compared with the true volumes. Fifty-six measurements were made. We found the accuracy of BVI 2000 sufficient to determine bladder volumes as either small or large. We found no systematic errors. No special training is required to use the scanner. The device is thus useful in most clinical situations when greater accuracy than indicated here is not necessary.

Evaluation Studies as Topic