PubMed Health⌕ Search

PubMed · 2761379

Missing pulse steady-state free precession.

Abstract

A fast imaging technique, missing pulse steady-state free precession (MP-SSFP), is described. MP-SSFP is one of a class of steady-state free precession techniques in which every nth RF pulse is missing. MP-SSFP has been implemented for the case where every third RF pulse is omitted: [-theta 1-r-theta 2-r-echo-r-]. A RF-refocused echo forms at the time of the missing pulse. This echo is less sensitive to field inhomogeneities than the gradient-recalled echoes used in most fast imaging methods. An analytical expression is obtained for the signal strength as a function of the flip angles theta 1 and theta 2, the interpulse interval tau, and the amount of interpulse dephase. The expression shows that theta 1 and theta 2 provide two degrees of freedom to optimize the signal-to-noise ratio and improve tissue contrast. Two different cases, theta 1 = theta 2 and theta 1 = -theta 2, are described to demonstrate the difference in contrast. The first case gives a strong signal from spins with short T1 and short T2 while the second case has contrast very similar to a conventional SSFP technique. The theoretical expression predicts that the signal consists of multiple components which may be observed experimentally by adjusting the gradient pulses.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Patz, S T Wong, M S Roos. 1989. Missing pulse steady-state free precession.. https://doi.org/10.1002/mrm.1910100205

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multidetector CT and dentascan software: dosimetric evaluation and technique improvement.

PURPOSE: The development of new operative techniques in oral and maxillofacial surgery within the last few years has led to an increasing demand for Dentascan examination, also in paediatric patients. It is necessary to modify acquisition parameters to reduce the absorbed dose. The aim of this study was to define a Dentascan protocol in which a reduced X-ray dose could be used. MATERIALS AND METHODS: Dosimeters were applied to the eyes, mouth, parotid glands, thyroid and back of the neck of an anthropomorphic Plexiglas phantom that underwent multidetector computed tomography (MDCT) Dentascan examinations. Both 120kV and 80 kV were used to study the mandibular and maxillary arches. RESULTS: Examinations obtained with the 80 kV protocol showed a ten-fold reduction in the absorbed dose, without affecting image quality. CONCLUSIONS: We suggest a Dentascan protocol that reduces the X-ray dose administered to the patient while ensuring the same high diagnostic accuracy.

Head↗