The nonextractable tined endocardial pacemaker lead.

Abstract

With the advent of the tined pacemaker electrode to improve endocardial fixation, increasing difficulty in extracting them when needed has resulted in reports of serious complications. The authors reviewed their experience between January 1975 and January 1985. During this 10 year period, 942 pacemakers were inserted and 73 were reoperated upon. In the reoperations, repositioning or removal of tined electrodes was attempted 28 times. Repositioning or removal was not possible in 12 of the 28 cases (43%). In 22 of 28, the attempts to remove tined leads were carried out more than one month after the original implantations and in this group the failure rate was 54.5% (12 of 22). All attempts of removal within one month of implantation were successful (six of six). No leads were retained during the period between January 1984 and January 1985. All 12 retained leads were followed-up for five years, five of which were retained in the presence of pacemaker pocket infections. After removal of the power pack and lead distal to the cephalic or subclavian vein inlet, control of infection was achieved in all five cases. One patient was noted to have the retained lead migrate into the right pulmonary artery but was asymptomatic at 35 months after catheter migration was detected. Until now, no thoracotomy for lead extraction has been required in this series.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Shennib, R C Chiu, M Rosengarten, P Blundell, H Scott, D S Mulder. 1989. The nonextractable tined endocardial pacemaker lead.. https://pubmed.ncbi.nlm.nih.gov/2790576/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The development of a multichannel electrode array for retinal prostheses.

The development of a multielectrode array is the key issue for retinal prostheses. We developed a 10 x 10 platinum electrode array that consists of an 8-microm polyimide layer sandwiched between 5-microm polymonochloro-para-xylylene (parylene-C) layers. Each electrode was formed as a 30-microm-high bump by Pt/Au double-layer electroplating. We estimated the charge delivery capability (CDC) of the electrode by measuring the CDCs of two-channel electrode arrays. The dimensions of each electrode of the two-channel array were the same as those of each electrode formed on the 10 x 10 array. The results suggest that for cathodic-first (CF) pulses, 80% of electrodes surpassed our development target of 318 microC/cm2, which corresponds to the charge density of pulses of 500 micros duration and 200 microA amplitude for a 200-microm-diameter planar electrode.

Electrodes, Implanted↗

Improved version of the printed circuit board (PCB) modular multi-channel microdrive for extracellular electrophysiological recordings.

The modular multi-channel PCB microdrive was described some years ago, since then several improvements were introduced while using these drives. Utilizing several years of experience with the original PCB microdrive we redesigned it to improve its stability and usability. The application of the printed circuit board technology and the extensive use of flexible fused silica capillaries for fabrication of the microdrive are described in detail. The improved design led to a low cost and light-weight multi-channel microdrive with outstanding modularity for extracellular field, single unit or multiunit tetrode recording up to 64/128 channels.

Electrodes, Implanted↗