A DPA technique for simultaneously measuring bone, soft tissue, and fat content.

Abstract

Although conventional dual photon absorptiometry (DPA) techniques can be used to estimate fat and soft tissue content, such estimates are not possible where bone is present. We propose a method that can make these estimates in the presence of bone in the extremities of the body. The combination of this method with the conventional method should yield fat and soft tissue composition from most points within the body. The proposed technique simultaneously measures thicknesses of bone, soft tissue, and fat. These thicknesses are determined of bone, soft tissue, and fat. These thicknesses are determined from a combination of gamma-ray transmission data at two energies and a measurement of total tissue thickness. To test the technique, a feasibility study was performed with known thicknesses of aluminum (simulating bone), lucite (simulating tissue), and polyethylene (simulating fat). A variety of thicknesses of each material were employed (Al: 0-1.3 cm, lucite: 0-5 cm, polyethylene: 0-5 cm). The accuracies (standard errors of the estimates) of the calculated versus true thicknesses of aluminum, lucite, and polyethylene were 0.6%, 2.6%, and 2.5%, respectively. The estimates of "bone" thickness were insensitive to the presence of varying thicknesses of "fat." (In contrast, application of the conventional DPA method to the same gamma-ray transmission data yielded underestimates in "bone" thickness due to "fat" by as much as 11%.) For a 60 minute (whole body) scan time, the reproducibility of the measurements of the thicknesses of aluminum, lucite, and polyethylene were 0.4%, 1.0%, and 1.3%, respectively. All of these values are in a clinically useful range.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M M Goodsitt, R Murano, M L Richardson. 1989. A DPA technique for simultaneously measuring bone, soft tissue, and fat content.. https://doi.org/10.1097/00004424-198910000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗