PubMed Health⌕ Search

PubMed · 32160

Slow postcapillary pH changes in blood in anesthetized animals.

Abstract

To investigate the hypothesis that blood pH and PCO2 continue to change after the blood leaves an exchange capillary, we used a rapidly responding, pressure-insensitive, stopped-flow pH electrode apparatus. Arterial blood from an anesthetized dog or cat is drawn through the apparatus into a syringe. Syringe movement is then suddenly stopped. Temperature and pH of the blood in the electrode assembly are continuously monitored, both before and after blood withdrawal ceases. Hemolysis was reduced by coating all blood contact surfaces with silicone and fasting the animal overnight, anesthetizing it with crystalline pentobarbital sodium, and allowing it to ventilate spontaneously. After stopping withdrawal, pH of blood in the electrode chamber continued to change, rising 0.01 unit with t1/2 of 4.4 s. After lysed blood was returned to the animal to provide carbonic anhydrase to the plasma, no pH change was seen after stopping the flow. The small pH rise occurring in arterial blood in vivo is probably due in large part to disequilibrium of [H+] between red blood cells and plasma at the end of the pulmonary capillary, the equilibration process being rate-limited by the extracellular CO2 hydration-dehydration reaction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Bidani, E D Crandall. 1978. Slow postcapillary pH changes in blood in anesthetized animals.. https://doi.org/10.1152/jappl.1978.45.5.674. https://pubmed.health/record/pubmed%3A32160/slow-postcapillary-ph-changes-in-blood-in-anesthetized-animals

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

The weighted walking test as an alternative method of assessing aerobic power.

The aim of the present study was to determine maximal oxygen uptake (VO2max) directly during uphill walking exercise and to compare these values with those achieved during running and cycling exercise. Forty untrained students (20 males and 20 females) took part in three exercise tests. The running test was performed on a horizontal treadmill and the speed was gradually increased by 0.3 m . s(-1) every 3 min. The walking test was conducted on a treadmill inclined at 12% (speed of 1.8 m . s(-1)). The load was further increased every 3 min by the addition of a mass of one-twentieth of the body mass of the participant (plastic containers filled with water and added to a backpack carried by the participant). During the bicycle ergometry test, the workload was increased by 20 W every 2 min. All tests were performed until volitional exhaustion. During all tests, oxygen uptake, minute ventilation, tidal volume, respiratory frequency, heart rate, hydrogen ion concentration, base excess, and blood lactate concentration were analysed. The Pearson correlation coefficients between the weighted walking test and the commonly applied running and bicycle ergometry tests indicate a strong association with the new test in evaluating maximal oxygen uptake. The negligible differences in VO2max between the three tests for the male participants (running: 61.0 ml . kg(-1) . min(-1); walking: 60.4 ml . kg(-1) . min(-1); cycling: 60.2 ml . kg(-1) . min(-1)), and the fact that the females achieved better results on the walking test than the cycle ergometer test (running: 45.0 ml . kg(-1) . min(-1); walking: 42.6 ml . kg(-1) . min(-1); cycling: 40.1 ml . kg(-1) . min(-1)), confirm the suitability of the new method for evaluating aerobic power. The weighted walking test could be useful in the assessment of aerobic power in individuals for whom running is not advised or is difficult. In addition, the new test allows for determination of VO2max on small treadmills with a limited speed regulator, such as those found in specialist physiotherapy and fitness centres.

Acid-Base Equilibrium↗

Mandatory protocol for treating adult patients with diabetic ketoacidosis decreases intensive care unit and hospital lengths of stay: results of a nonrandomized trial.

OBJECTIVE: To determine the effect of a mandatory protocol for treating diabetic ketoacidosis. DESIGN: Chart review of patients treated before and after protocol implementation. SETTING: University-affiliated U.S. public teaching hospital. PATIENTS: A total of 241 consecutive nonpregnant patients >18 yrs old admitted to a medical intensive care unit for diabetic ketoacidosis between January 2000 and January 2005. INTERVENTION: Implementation of a mandatory treatment protocol in May 2003. MEASUREMENTS: Intensive care unit and hospital lengths of stay, time to correction of anion gap and ketone clearance, and hypoglycemic episodes. RESULTS: Before protocol implementation, the mean +/- sd intensive care unit and hospital lengths of stay were 44 +/- 28 hrs and 91 +/- 73 hrs, respectively. After implementation, intensive care unit and hospital lengths of stay decreased 23% and 30%, to 34 +/- 18 hrs and 64 +/- 41 hrs, respectively (both p < .007). Time to anion gap closure and ketone clearance also decreased (both p < .05). No difference in the number of hypoglycemic episodes was observed. CONCLUSION: Implementing a mandatory protocol for treating adult patients with diabetic ketoacidosis decreases intensive care and hospital lengths of stay and time to anion gap closure and ketone clearance, without increasing the rate of hypoglycemia.

Acid-Base Equilibrium↗