PubMed Health⌕ Search

PubMed · 3269612

[Minigraph, its structure and applications].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Kleinrok, W Kedra, T Lipnicki. [Minigraph, its structure and applications].. https://pubmed.ncbi.nlm.nih.gov/3269612/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A validation of two orthognathic model surgery techniques.

In order to create an evidence-based orthognathic surgery planning protocol, an investigation of two popular model surgery techniques, the Lockwood keyspacer and the Eastman anatomically-orientated system was carried. This determined (a) the accuracy of positioning of the maxillary cast according to the prescribed treatment plan and (b) the relocation of the maxilla after a simulated Le Fort I down fracture osteotomy using the intermediate wafer as a guide. Fifteen patients-five Class II division 1, five Class II division 2, and five Class III-were included in the study. All the measurements were taken with Erickson's vertically mounted electronic caliper and variations from the treatment plan were analysed. The mean model surgery positioning errors +/- SD (mm) were: (i) vertical plane-Lockwood -0*8 +/- 1*6 and Eastman 0*00 +/- 1*0 (P = 0*0001); (ii) anteroposterior plane-Lockwood 1*2 +/- 1*8 and Eastman -0*1 +/- 1*4 (P = 0*05); and (iii) transverse plane-Lockwood 0*9 +/- 0*9 and Eastman 1*0 +/- 0*9 (P = 0*34). After the simulated osteotomy, the mean errors +/- SD were: (i) vertical plane-Lockwood -0*5 +/- 1*5 and Eastman 0*3 +/- 1*1 (P = 0*001); (ii) in anteroposterior plane-Lockwood 0*8 +/- 2*0 and Eastman 0*7 +/- 1*0 (P = 0*89); and (iii) transverse plane-Lockwood 0*8 +/- 0*6 and Eastman 0*7 +/- 0*5 (P = 0*83). The Eastman technique was relatively better especially in the vertical plane. The variations from the treatment plan were on the whole anatomically small, but in some cases could be clinically significant.

Dental Articulators↗

Functional occlusion: II. The role of articulators in orthodontics.

Opinion is divided on whether there is a place for the use of semi-adjustable dental articulators in orthodontics. In this review we explore the validity and reproducibility of the techniques involved in mounting study models on a semi-adjustable dental articulator. We also look at the role of articulated study models in orthodontic diagnosis and treatment planning, in the finishing stages of orthodontics and in planning for orthognathic surgery. We report that each of the many stages involved in mounting study models on a semi-adjustable articulator is a potential source of error and that only if the technique is carried out with a high degree of accuracy is it worth the additional chairside time.

Dental Articulators↗