Automatic testing of the visual field using electro-oculographic potentials.

Abstract

The central visual field is tested using static perimetry on a tangent screen located 1 m from the patient. During the test electro-oculographic (EOG) potentials, associated with eye movements, are recorded. For this purpose two pairs of electrodes are placed in such a way that one pair records the vertical and the other the horizontal component of the EOG potential. The EOG signals that are produced when the tested eye moves toward the light target on the screen are digitized and fed into a computer programmed to relate each pair of signals to the specific lamp on the tangent screen. The results of the test appear on a computer-printed chart that shows the distribution of the lamps on the testing board together with the information whether the lamp was seen by the subject. This method of visual field testing is both objective and automatic.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Armon, J Weinman, A Peleg, U Ticho, H Zauberman, D Mallek. 1977-04-29. Automatic testing of the visual field using electro-oculographic potentials.. https://doi.org/10.1007/bf01569292

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Oligonucleotide labeling methods. 3. Direct labeling of oligonucleotides employing a novel, non-nucleosidic, 2-aminobutyl-1,3-propanediol backbone.

Novel CE-phosphoramidite (7a-e) and CPG (8a, c, d, e) reagents have been prepared from a unique 2-aminobutyl-1,3-propanediol backbone. The reagents have been used to directly label oligonucleotides with fluorescein, acridine, and biotin via automated DNA synthesis. The versatile 2-aminobutyl-1,3-propanediol backbone allows for labeling at any position (5', internal, and 3') during solid phase oligonucleotide synthesis. Multiple labels can be achieved by repetitive coupling cycles. Furthermore, the 3-carbon atom internucleotide phosphate distance is retained when inserted internally. Using this method, individual oligonucleotides possessing two and three different reporter molecules have been prepared.

Automation

[Routine application of HLA class II oligotyping. Value of automatization].

HLA class II typing by DNA amplification and hybridization with allele-specific oligonucleotides has led to an improvement of the overall typing accuracy. In an attempt to apply this procedure to a large-scale analysis, we sought to implement an automation system using the Biomek 1,000 robotic work-station. This system allows a rapid preparation of many consecutive samples and avoids the risk of human errors. It is now routinely used in several laboratories.

Automation