Multisample parallel array fraction collector: application in DNA alkaline elution studies.

Abstract

A fraction collector designed specifically to be compatible with the analytical techniques of alkaline and neutral elution of DNA from carcinogen-treated cells is described. This apparatus, which is operated by microchip controls, permits simultaneous collection of as many as 20 eluted samples directly into standard- or small-size scintillation vials contained in manufacturer's shipping cartons. This instrument saves operator time, offers considerable flexibility, and has several fail-safe features.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Peak, W J Eisler. 1988-02-15. Multisample parallel array fraction collector: application in DNA alkaline elution studies.. https://doi.org/10.1016/0003-2697(88)90272-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid breakthrough measurement of void volume for field-flow fractionation channels.

A peak breakthrough technique is described and evaluated for measuring the void volume of field-flow fractionation (FFF) channels, particularly those used for flow FFF. This technique uses a high-molecular-mass macromolecular or particulate probe that can be displaced rapidly by flow through the FFF channel with minimal transverse diffusion. The particles that emerge first are those carried through the entire length near the channel centerline at the apex of the parabolic flow profile. These particles generate a sharp breakthrough profile. The measured breakthrough time is two thirds of the void time, thus making it possible to calculate both the void time and the associated void volume. This method, although applicable to all FFF channels (and capable of extension to open tubes), is particularly useful for flow FFF because conventional low-molecular-mass void probes can diffuse into the permeable walls and thus distort void measurements. The theoretical basis of the breakthrough technique and an explanation for the sharpness of the breakthrough front are given. A method for compensating for deviations from perfect sharpness is developed in which the breakthrough time is identified with the time needed to reach 85-88% of the breakthrough peak maximum. Preliminary experimental results are shown using various protein probes in four different FFF channel systems.

Chemical Fractionation

Cofractionation of the TATA-binding protein with the RNA polymerase III transcription factor TFIIIB.

We have investigated the requirement for TBP (TATA-binding protein) in transcription mediated by RNA polymerase III (pol III) in fractionated HeLa cell extracts. Two activities, TFIIIB and TFIIIC, found in phosphocellulose fractions PC B and PC C respectively, have been defined as necessary and sufficient, with pol III, for in vitro transcription of tRNA genes. Depletion of TBP from PC B, using antibodies raised against human TBP, is shown to inhibit the pol III transcriptional activity of the fraction. Furthermore, TBP is present in fractions with human TFIIIB activity, and a proportion of TBP cofractionates with TFIIIB over four chromatographic purification steps. TFIIIB fractions are capable of supplying TBP in the form necessary for pol III transcription, and cannot be substituted by fractions containing other TBP complexes or TBP alone. The use of a 5S RNA gene and two tRNA templates supports the general relevance of our findings for pol III gene transcription. Purified TFIIIB activity can also support pol II-mediated transcription, and is found in a complex of approximately 230kD, suggesting that TFIIIB may be the same as the previously characterized B-TFIID complex (1,2). We suggest that transcription by the three RNA polymerases is mediated by distinct TBP-TAF complexes: SL1 and D-TFIID for pol I and pol II respectively, and TFIIIB for pol III.

Chemical Fractionation

Strategies for the identification of non-polar toxicants in aqueous environmental samples using toxicity-based fractionation and gas chromatography-mass spectrometry.

Toxicity-based fractionation is a useful tool for the isolation and identification of non-polar organic compounds that are present at toxic concentrations in aqueous environmental samples. Methods for isolating such toxicants from the aqueous sample matrix and techniques for fractionating the compounds for the purpose of reducing the complexity of the sample matrix and thus facilitating identification are evaluated. Strategies for analyzing gas chromatographic-mass spectrometric data and confirming toxicant identification are presented. Studies that use toxicity-based fractionation for identifying the cause of toxicity in aqueous environmental samples such as municipal and industrial wastewater treatment plant effluents and ambient waters are discussed.

Chemical Fractionation