PubMed HealthSearch

PubMed · 3375498

[Osteoid osteoma with acetabular localization].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Granone. 1988. [Osteoid osteoma with acetabular localization].. https://pubmed.ncbi.nlm.nih.gov/3375498/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The Harris-Galante porous-coated acetabular component with screw fixation. An average ten-year follow-up study.

Two hundred and thirty-seven consecutive primary acetabular reconstructions were performed, in 213 patients, with use of a Harris-Galante porous-coated acetabular component with screw fixation between January 1984 and December 1987. Twenty-four patients (twenty-seven hips) died before a minimum duration of follow-up of eighty-four months, five patients (five hips) were too ill to return for a detailed follow-up examination at the time of the study, four patients (four hips) refused clinical and radiographic follow-up (but one of these patients had more than eighty-four months of follow-up for one side of a bilateral total hip replacement), two patients (two hips) were lost to follow-up, and two patients (two hips) refused radiographic follow-up but had adequate clinical follow-up. In addition, one patient who had had a bilateral total hip replacement had a resection arthroplasty on one side because of a late infection 115 months after the index procedure. Thus, 196 hips (83 per cent) in 177 patients were available for radiographic and clinical review after an average duration of follow-up of 122 months (range, eighty-four to 155 months). The average age of these 177 patients at the time of the operation was fifty-nine years (range, twenty-three to eighty-seven years). Eight well fixed acetabular shells (4 percent) were revised: three were revised because of dissociation of the liner in association with fractures of the tines, three were revised during revision of the femoral component, and two were revised because of retroacetabular osteolysis. In eight other hips, the acetabular liner was exchanged during revision of a loose femoral component. No acetabular component migrated, was classified as radiographically loose, or was revised because of aseptic loosening. There was no evidence of fragmentation or disruption of the titanium porous mesh of any cup. One of 528 screws broke. There were no complications associated with the insertion of the acetabular fixation screws. Osteolytic lesions were identified adjacent to nine (5 percent) of the 188 acetabular components that were in place at the time of the most recent examination. One hip, which had discontinuous osteolytic lesions in all three acetabular zones, was treated with bone-grafting around the well fixed acetabular component. Eight hips had a discontinuous radiolucent line that was 1.0 millimeter wide or less in all three zones and another two had a continuous radiolucent line that was 0.5 millimeter wide in all three zones. The average Harris hip score for the 188 hips (169 patients) that did not have revision of the acetabular shell improved from 47 points (range, 22 to 71 points) preoperatively to 89 points (range, 35 to 100 points) at the time of the latest examination. One hundred and thirty-four hips had an excellent result; twenty-six, a good result; nineteen, a fair result; and nine, a poor result. All nine hips that had a poor result were in patients who had other factors, unrelated to the acetabular component, that contributed to the low Harris hip score. In the present study, the Harris-Galante porous-coated acetabular component continued to provide excellent fixation and clinical results for most patients at an average of approximately ten years after the operation.

Acetabulum

Medial protrusio technique for placement of a porous-coated, hemispherical acetabular component without cement in a total hip arthroplasty in patients who have acetabular dysplasia.

Twenty-four hip replacements were performed with use of a medial protrusio technique to stabilize the fit of a hemispherical metal shell in the acetabulum in nineteen patients who had dysplasia of the hip. All of the hips were followed for a minimum of five years (average, seven years; range, five to thirteen years). Six of the hips were type I, seven were type II, eight were type III, and three were type IV according to the criteria of Crowe et al. The acetabular cup was implanted with the medial aspect of its dome beyond the Kohler line (drawn from the ischium along the ilioischial line) in all hips. An autogenous graft sculpted from the femoral head was used to cover 15 to 30 percent of the superolateral portion of the cup in one type-I hip, four type-III hips, and one type-IV hip. The need for these six bone grafts could have been avoided by reaming two to three millimeters more medially or by allowing 20 percent of the superolateral portion of the cup to be uncovered. Sixty to 84 percent of each bone graft was resorbed, effectively leaving the superolateral portion of the cup uncovered. The amount of the surface of the cup that was beyond the Kohler line averaged 41 percent for the six type-I hips, 43 percent for the seven type-II hips, 41 percent for six of the type-III hips, and 44 percent for one of the type-IV hips. Crossing of the ilioischial and iliopubic lines was noted on the radiographs of two type-III and two type-IV hips. Radiographs of two type-I hips and one type-II hip showed 7 to 17 percent of the surface of the dome of the cup through the internal pelvic wall (beyond the iliopubic line). None of the twenty-four metal shells were revised. A reoperation was performed on two hips to exchange a worn polyethylene insert, and three femoral components that had been fixed without cement were revised because of mechanical loosening. Wear averaged 0.26 millimeter per year in the fourteen hips that had a titanium femoral head and 0.09 millimeter per year in the nine hips that had a cobalt-chromium femoral head. The remaining hip had a ceramic femoral head, and the wear rate was 0.09 millimeter per year. The medial protrusio technique is a predictable, reproducible method for obtaining fixation of a porous-coated, hemispherical acetabular component in a dysplastic acetabulum. The technique permits the use of a porous-coated (bone-ingrowth) component; avoids the use of support bone graft and thereby reduces the operative time; facilitates rehabilitation by permitting earlier weight-bearing of the hip; and permits the use of a modular bearing surface, which may allow future exchange of only this surface rather than revision of the entire acetabular component because of excessive wear.

Acetabulum

Cementless coated and noncoated Mathys acetabular cups: radiographic and histologic evaluation.

This study evaluated 185 cementless Mathys coated and uncoated acetabular cups inserted for total hip replacement since September 1984. All of the cups were high-density polyethylene. Sixty were uncoated (group A), 96 were coated with hydroxyapatite (group B), and 29 were coated with titanium (group C). Cup survival was assessed clinically, histologically, and radiographically, and a computer-assisted EBRA method was used to evaluate cup migration. After a mean follow-up of 8 years, five cups in group A that had previously shown migration were revised as a result of aseptic loosening, while no loosening of hip sockets occurred in groups B and C. These results suggest that Mathys cups should be used only if coated with hydroxyapatite or titanium. Furthermore, the histologic evaluation in four cups from groups B and C revealed normal bone formation without inflammation or fibrotic tissue around the cups, promising long-term survival.

Acetabulum