PubMed HealthSearch

PubMed · 3445813

Electroepilation using insulated needles.

Abstract

We have practiced electroepilation using insulated needles on approximately 500 patients over a five-year period using electroepilation equipment that produced a thermolysis (high frequency) current. Our patients were given three to eight treatments at two-week to three-month intervals. The results for 73 patients, observed six months to three years after their last epilation, showed little or no hair regrowth and no scarring. We attribute our success to concomitant factors: We were able to destroy the hair papilla using a long-duration, high-frequency current while protecting the skin surface from scarring by using an insulated needle.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Kobayashi, G Kamiyama. 1987. Electroepilation using insulated needles.. https://doi.org/10.1007/bf01575514

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiation exposure to patients and medical personnel during radiofrequency catheter ablation for supraventricular tachycardia.

Radiofrequency catheter ablation is an effective alternative to medical therapy for patients with supraventricular arrhythmias. The purpose of this study was to determine the risks to the patient and to medical personnel due to radiation exposure from fluoroscopy during radiofrequency ablation of supraventricular tachycardia. One hundred eight consecutive patients with Wolff-Parkinson-White syndrome or atrioventricular nodal reentry who underwent the ablation procedure were studied. The ablation procedure was successful in 95% of the patients studied. Preexcitation or supraventricular tachycardia recurred in 5% of the patients during a mean follow-up of 9 +/- 4 months. The mean fluoroscopy time was 50 +/- 31 minutes. An anthropomorphic radiologic phantom was used to determine organ exposure and the effective dose equivalents for the patient and medical personnel. The patient's effective dose equivalent during a representative ablation procedure was 1.7 rems, which is comparable to other invasive cardiovascular procedures. The risk of inducing a fatal cancer from this exposure is 1 chance in 745, which is 1% of the spontaneous risk. The risk of a serious birth defect is 1 chance in 80,000, which is 0.1% of the current incidence of serious birth defects in the United States. The cardiologist who receives the highest exposure among medical personnel, would incur 1.8 mrems per case or 450 mrems per year if 250 procedures were performed. This exposure is 9% of the recommended annual limit. These results demonstrate the efficacy of radiofrequency energy ablation of supraventricular tachycardia and confirm that radiation exposure to patients and medical personnel is within established guidelines.

Electrocoagulation