PubMed HealthSearch

PubMed · 3460620

Posterior composites.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D J Cowan. 1986-07-19. Posterior composites.. https://doi.org/10.1038/sj.bdj.4805891

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic measurement of temperature change during resin composite polymerization in vivo.

OBJECTIVES: To use the technique of infrared thermography for non-invasive monitoring of temperature changes during polymerization of resin composite by measuring the infra-red emission from the surfaces of resin composite restorations during photocuring. METHODS: In this study 10 patient volunteers had resin composite restorations placed in upper incisor teeth and during photocuring the temperature rise within the composite was measured using the Thermovision 900 infra-red scanning system. RESULTS: The results demonstrate that the exotherm is almost instantaneous, occurring as soon as the light source is activated and rising to a peak at approximately 30 s before levelling off. The measurements suggest that a maximum temperature increase of 12 degrees C could occur, although this may only be for a short period (< 15 s). CONCLUSION: The range of temperature rise measured in this study (mean 5.4 degree C +/- 2.5 degree C) would suggest that the pulp may be endangered by the temperature rise which occurs during resin composite polymerization in vivo.

Composite Resins

Light curing unit effectiveness assessed by dental radiometers.

OBJECTIVES: The purpose of this investigation was to assess the effectiveness of five commercially available hand-held dental radiometers and a computer-based experimental radiometer. METHODS: Light intensity of five visible light activation units was determined using the dental radiometers. The influence of curing light intensity on depth of cure of a hybrid composite material was determined using a digital penetrometer. RESULTS: The radiometers evaluated varied with respect to sensor aperture diameter, scale readings (analogue or digital) and the units of measurement (arbitrary or mW cm2). The experimental computer-based radiometer allowed continuous recording of intensity against time; thus the light output could be monitored over the entire irradiation period. CONCLUSIONS: When light intensity readings were normalized with regard to a standardized light sensing device aperture of 4 mm diameter, a linear relationship was found between depth of cure and the logarithm of the intensity of the light. The results of this investigation support the use of dental radiometers for periodically monitoring visible light activation units.

Composite Resins