PubMed Health⌕ Search

PubMed · 3550821

Stability study of prostacyclin in solution.

Abstract

The proton-catalyzed hydrolytic decomposition of prostacyclin was assayed by UV spectroscopic and HPLC methods. Changes of the absorbance in aqueous solutions were measured at 220 nm. HPLC studies were performed on C18 column using NH4Cl (0.03 mol X l-1)/NH4OH (0.03 mol X l-1)/methanol (1 : 1 : 4) eluent. Temperature and pH dependence of the hydrolytic process was determined. Effects of alcohol and glycols on the degradation rate were studied.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Rácz, J Mezei, S Küttel. 1986. Stability study of prostacyclin in solution.. https://pubmed.ncbi.nlm.nih.gov/3550821/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurements of drug-protein binding by using immobilized human serum albumin liquid chromatography-mass spectrometry.

An HPLC/MS based method was used for fast and convenient determination of drug plasma-protein interactions in early drug discovery screening by employing a human serum albumin affinity column. Results from this methodology were compared with data from ultrafiltration or dialysis methods, and good agreement was observed. A compound not suitable for ultrafiltration due to the very high non-specific binding to artificial membrane of ultrafiltration device was also successfully analyzed by this method, and the protein binding determined by this chromatography method was very similar to data obtained by dialysis technique employing biological membranes. The immobilized HSA column LC/MS method also proved to be more reproducible and precise compared to ultrafiltration method in drug protein binding measurements.

Chromatography, High Pressure Liquid↗

Transient kinetics of the reaction catalysed by magnesium protoporphyrin IX methyltransferase.

Magnesium protoporphyrin IX methyltransferase (ChlM), an enzyme in the chlorophyll biosynthetic pathway, catalyses the transfer of a methyl group to magnesium protoporphyrin IX (MgP) to form magnesium protoporphyrin IX monomethyl ester (MgPME). S-Adenosyl-L-methionine is the other substrate, from which a methyl group is transferred to the propionate group on ring C of the porphyrin macrocycle. Stopped-flow techniques were used to characterize the binding of porphyrin substrate to ChlM from Synechocystis PCC6803 by monitoring tryptophan fluorescence quenching on a millisecond timescale. We concluded that a rapid binding step is preceded by a slower isomerization of the enzyme. Quenched-flow techniques have been employed to characterize subsequent partial reactions in the catalytic mechanism. A lag phase has been identified that has been attributed to the formation of an intermediate. Our results provide a greater understanding of this catalytic process which controls the relative concentrations of MgP and MgPME, both of which are implicated in signalling between the plastid and nucleus in plants.

Chromatography, High Pressure Liquid↗

Determination of dihydroergocryptine in human plasma and urine samples using on-line sample extraction-column-switching reversed-phase liquid chromatography-mass spectrometry.

A rapid and sensitive assay for the determination of dihydroergocryptine (DHEC) in human plasma and urine samples with dihydroergotamine (DHET) as the internal standard was developed. The procedure employs on-line sample preparation using an extraction pre-column and an octadecylsilylsilica (ODS) analytical column. After centrifugation human plasma or urine were injected onto the pre-column, concentrated and extracted, back-flushed onto the analytical column and eluted with a binary methanol--aqueous formic acid gradient. Either determination of DHEC as well of its mono- and dihydroxy-metabolites was performed by measurement of the signal responses from MS detection in the selected reaction monitoring (SRM) mode using the transition of the respective parent ions to the common daughter ion at m/z=270.2 amu. The limit of quantitation (LOQ) for determinations of DHEC in both plasma and urine were 25 pg/ml for injected sample volumes of 400 microl. Proportionality of signal responses versus concentration was accomplished within the range of 25-1000 pg/ml. Recovery of target analyte from plasma was 99%. Mean values of the coefficients of variation (CV) for the target analyte in plasma ranged from 1.7 to 13.8% (within-day) and 5.0 to 9.1% (between-day) and accuracy from 91.7 to 102.6% for the within-day and from 95.8 to 98.8% for the between-day measurements. The corresponding values for determinations in urine were 1.7-14.5% (within-day) and 5.3-11.8% (between-day) for CV and 95.8-110.7% (within-day) and 100.1-104.6% (between-day) for accuracy.

Chromatography, High Pressure Liquid↗